INSTRUCTION MANUAL VCC-6574 COLOR CCD CAMERA About this manual Before installing and using the camera, please read this manual carefully. Be sure to keep it handy for later reference.
Page 2
In order to obtain warranty service, the product must be delivered to and picked up from an Authorized Sanyo Service Center at the user’s expense, unless specifically stated otherwise in this warranty. The names and addresses of Authorized Sanyo Service Centers may be obtained by calling the toll-free number listed below.
Depending on the conditions of use, installation and environment, please be sure to make the appropriate settings and adjustments. If you need help with installation and/or settings, please consult your dealer. CONTENTS INFORMATION TO USER... 2 PRECAUTIONS... 3 PARTS NAMES ... 4 CONCERNING AUTO-IRIS LENSES ...
(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by Sanyo may void the user’s authority to operate this camera. English...
Do not use the camera if smoke or a strange odour comes from the unit, or if it seems not to function correctly. Disconnect the power cord immediately, and consult your dealer (or a Sanyo Authorized Service Centre). Do not open or modify Do not open the cabinet, as it may be dangerous and cause damage to the unit.
PARTS NAMES Connect this connector to a device such as a VCR or monitor with a VIDEO IN connector. When using two cameras or more, the image on the monitor may roll vertically when switching sources. This rolling can be minimized by turning this volume. Comes on when the power to the camera is on.
Page 7
PARTS NAMES Lens mount cap The cap is installed to protect the lens mount section. Remove the lens mount cap before installing a lens (sold separately). Flange-back adjustment screw (FLANGE BACK ADJ.) Flange-back lock screw (FLANGE BACK LOCK) Camera installation bracket The bracket can be fixed at the top or bottom of the camera.
Page 8
PARTS NAMES This 4-pin connector is used to send the DC control signal and power supply to an auto-iris type lens. These settings are for when using a 1/3 inch CS mount DC (without EE internal amplifier) type lens. However, if due to installation conditions or environment the settings may need to be modified for best results (see "SETTINGS").
Depending on the type of lens used, the lens may not perform properly. In such a case, adjust the LEVEL volume on the lens casing to correct. English 1/3 inch Sanyo DC type lens VIDEO type lens Standard angle, f= 9 mm...
MOUNTING THE LENS Please use a DC type auto-iris lens (sold separately). Check the lens mount Do not use a lens if the length “ camera and prevent proper installation. C mount type lens CS mount type lens ” is more than Remove the lens mount cap from the camera.
Page 11
MOUNTING THE LENS Rewiring the lens cable in the lens iris plug Prepare the lens cable. Cut the cable at the plug, then remove approx. 8 mm of the cable sheath and strip about 2 mm from each wire. Install the lens iris plug. Solder the cable to the pins following the correct pin layout (refer to the table and illustrations), then close the plug cover.
CONNECTIONS (Video signal connections) : VIDEO IN : VIDEO OUT Basic connection for monitoring or recording The peripheral devices (VCR, monitor, lens, etc.), AC adaptor and cables are sold separately. Make the video signal connection between the camera and the monitor or time lapse VCR.
SETTINGS The illustration shows the factory default settings for the switches in the camera setup section. The camera settings are described on the assumption that a DC type auto iris lens is being used. If you are using a VIDEO type auto iris lens, be sure to read the Note which is given.
Page 14
SETTINGS Iris function setting This should normally be set to the down (AI) position. Use a manual or fixed iris lens and set the lens aperture to the shortest F stop. Set the switch 1 (IRIS) to the up (EI) position. Note: Please refer to the specifications for dynamic range of the electronic iris.
SETTINGS Backlight compensation setting Use an auto-iris lens and set the switch 4 to the up (ON) position, to engage the backlight compensation function. This camera has two different backlight correction functions: multi-spot photometry (MULT) and center focus photometry (CENT). The normal setting (switch 3) is the down (MULT) position, but you can change the switch 3 setting in accordance with the...
SETTINGS White balance adjustment Normally the switch 5 (WB) is set to the down (ATW: auto white balance) position and the white balance is adjusted automatically. If a manual white balance adjustment is necessary, follow the steps below. Set the switch 5 (WB) to the up (MANU) position, then adjust the color.
Before taking the camera for repairs, please check below to make sure that the camera is used correctly. If it still does not perform correctly, please consult your dealer or a Sanyo Authorized Service Centre. No picture on the monitor screen •...
However, in the event of a problem, the owner is advised not to attempt to make repairs or open the cabinet. Servicing should always be referred to your dealer or Sanyo Authorized Service Centre. 0.5 mm : 24 V AC, 60 Hz : Approx.
Page 19
SPECIFICATIONS Dimensions 108.5 99.5 1/4”–20 UNC Features and specifications are subject to change without prior notice or obligations. English...