3. Turn on the power switch in the cabinet.
The recommended current specification for the external power circuit breaker connected to
the server is as follows:
AC power supply: 32 A
DC power supply: 63 A
4. Power on the server.
The power-on methods of the server vary according to the following scenarios:
The power supply units (PSUs) are properly installed but not powered on.
Connect the external power supply to the PSUs. Then the server will power on with the
PSUs.
The default value of System State Upon Power Supply is Power On, which indicates
that the server automatically powers on after power is supplied to the PSUs. To change
the value of System State Upon Power Supply, log in to the iBMC WebUI and choose
System > Power > Power Control.
The PSUs are installed properly and powered on. The server is in the standby state (the
power button/indicator is steady yellow).
− Press the power button/indicator
to power on the server.
− Power on the server using the iBMC CLI.
Log in to the iBMC CLI, run the ipmcset -d powerstate -v 1 command, and enter y or
Y to power on the server.
− Power on the server using the iBMC WebUI.
Log in to the iBMC WebUI, choose System > Power > Power Control, click Power On,
and click OK to power on the server.
− Power on the server using the remote virtual console.
Log in to the remote virtual console. On the KVM screen, click
toolbar, select Power On, and click Yes to power on the server.
5. Check the status of the indicators.
If the power indicator
is steady green, the PSUs are powered on.
4
If the power button/indicator
5 Follow-up Operations
After installing the server into the cabinet and powering it on, perform other necessary
operations such as configuring the server. For details, see the
(Model 1280).
Scan the QR code to visit the Huawei technical support website.
Website:
https://support.huawei.com/enterprise/en/
Under TECHNICAL SUPPORT, enter (model 1280) to search.
6 Appendix: Hazardous Substance Statement for
Electronic and Electrical Products
Part
Cd
PCBA
Cables
Accessories
Equipment
Batteries*
This statement for electronic and electrical products complies with SJ/T 11364.
○: all homogenous part materials under GB/T 26572 hazardous substance limit
×
: at least one homogenous material exceeds GB/T 26572 hazardous substance limit
*: when in use by the product
or
on the
is steady green, the server is powered on.
TaiShan 200 Server User Guide
Hazardous Substances
Pb
Hg
Cr (VI)
PBBs
PBDEs
×
×
×
×
×
5