Other Tips

1. DCA / VCA FADERS
To have DCA (or analog VCA) style Fader Masters, first check the INPUT FADER MASTER box near the top of the IN
FADER GROUP display page. Then select the [REMOTE] FADER LAYER, and assign USER ASSIGNABLE LAYER as
the TARGET. After that, all the GROUP MASTER FADERS can be selected to appear on the REMOTE FADER
LAYER, along with any other channels chosen by the user.
2. MUTE MASTER Switches
The USER DEFINED KEYS can be programmed to control the MUTE GROUP MASTER buttons. But first the
INPUT MUTE MASTER and OUTPUT MUTE MASTER boxes must be checked in the MUTE GROUP display
menu. Then the Mute Groups will behave in a similar way to those on a typical analog console: each channel's [ON]
button is independent, while the Mute Master buttons will mute all the assigned channels, causing their [ON] buttons
to flash.
3. SCENE MEMORY Auto Update
In the PREFER1 page of the [DIO/SETUP] menu, the 'Scene MEM Auto Update' option can be found. When this is
switched on, the last mixing settings are memorized just before the next Scene is recalled.
Then when a previous Scene is recalled, its last settings are recalled first. Press RECALL again to access the original
scene settings. So two memories for each scene are kept: the original settings, and the last settings.