Salt Container - Removal; Circulation Pump - Removal - Miele G2000 Technical Information

Hide thumbs Also See for G2000:
Table of Contents

Advertisement

G1000 / G2000 Dishwashers
1. Remove the left side panel (5.1.1).
2. Remove the drip pan (5.1.2).
3. Remove the connecting strip (5.3.4).
4. Disconnect the electrical connector from the solenoid.
5. Twist the reactivation valve 90° clockwise.
6. Remove the reactivation valve upwards.
5.4.13

Salt Container - Removal

1. Remove the salt container cap from the cabinet interior.
2. Remove as salt water from the salt container.
3. Remove the sealing ring.
4. Close the opening with the service cap (available through Miele).
5. Unscrew the retaining nut.
6. Remove the left side panel (5.1.1).
7. Remove the drip pan (5.1.2).
8. Remove the heating relay from the water inlet mixer.
9. Place a cloth or towel under the plug connections between the water inlet mixer
and the water softener.
10. Disconnect the connection with hose clip to the water inlet mixer from the resin
chamber.
11. Disconnect the plug connections for the salt monitor from the salt container.
12. Remove the wiring harness from its guide.
13. Pull off the salt container in the direction of its connection stub.
14. Close the connection stub on the salt container with the service stopper
(available through Miele).
Reassemble by following these instructions in reverse order. The following should
also be noted.
1. Fit the salt container, center it with the retaining nut and screw tight.
2. Apply soap solution to the O-rings as a slip lubricant and fit them on the water
inlet mixer stubs.
3. Refit the wiring harness in its guides on the salt container and water inlet mixer.
4. Check all electrical components in the drip pan area for residual moisture. Dry –
as necessary.
5. Thoroughly remove any traces of salt / water that may have leaked.
6. After reassembly, fill the salt container with salt and water.
7. A short program, e.g. Quick wash 104°F, without load should be run to remove
any salt residues.
8. Ensure all hardware is secured.
5.4.14

Circulation Pump - Removal

1. Remove the motor holder retaining screw from the rear panel.
89