Fault Repair Summary; No Power - Main Switch Is On; Display Shows "Close Salt Reservoir Cap; Drain Pump Switches On And Off At Short Intervals - Miele G2000 Technical Information

Hide thumbs Also See for G2000:
Table of Contents

Advertisement

Technical Information
6.8

Fault Repair Summary

6.8.1

No Power - Main Switch Is On

1. Check for 120 VAC from wall outlet. If hard wired check for voltage at terminal
X3/1. If no voltage is present, check:
a. Circuit Breaker Panel or "Fuse Box.
b. If hard wired check for proper connection at terminal X3/1
2. Check for power to the electronic unit.
a. If power is present, go to step 3.
b. If no power is present, check wire continuity between electronic
3. Check main switch S2.
a. If switch is inoperative, replace switch. For units where the switch
4. Check the door contact switch S24.
a. If the door contact switch has power, replace the electronic board.
6.8.2

Display shows "Close Salt Reservoir Cap"

Fault code F86 is logged in fault memory
The reed switch is open. The display shows Close salt reservoir cap.
1. Insure the salt container lid on inside door is closed.
2. Check to see if the magnet is missing off of lid. Replace container lid if
magnet is missing.
3. Check reed switch and connections. Replace reed switch if necessary.
6.8.3

Drain Pump Switches On and Off at Short Intervals

The drain pump operates with 1 sec. on and 4 sec. off
a. Electronic unit fault, replace the electronic unit.
board and terminal X3/1.
is part of the electronic board. Replace the electronic board.