Download Print this page

Advertisement

Quick Links

Quick Start Guide
Relion® 630 series
4
5
1
Display
2
Self-supervision and
protection indicator LEDs
3
Programmable LEDs
4
Function buttons
5
Object control buttons
6
Escape / Cancel
Navigation buttons
7
8
Enter
9
Authorization
10
Clear
11
LED text view
12
Menu
13
Remote / Lemote
14
Help
15
Front communication port
2
1
6
Default view can be selected from e.g. single line diagram (SLD), measurement, events
Ready-LED steady: OK, Ready-LED flashing: Internal Relay Fault (IRF), Start-LED steady: protection started,
Start-LED flashing: protection function blocked, Trip-LED: protection operated
Can be programmed for alarming and indication with latching and/or flashing features in 3 colors
Can be configured either as menu shortcuts or control buttons
Press open/close and confirm by pressing enter. If there is more than one controllable object select the object
first with navigation buttons. Note: R/L button has to be in Local mode.
Used for canceling actions and leaving setting mode without saving the values. Returns back to menu.
Left = go back, Right = go further, Up = scroll up, Down = scroll down. Up/down can also be used when
selecting controllable objects like breakers and switches in single line diagram.
Entering to parameter setting mode and confirming new values or selection in dialogs
If authorization is used you can log in or log out using this button
Clearing events and indications, see next page for further details
Multipage programmable LED text view. Press to see the 3 sets of 15 LED texts.
Switch views in between the main menu and default view
Changes the control between Local/Remote
View help menu
RJ-45 connection
8
7
9
3
11
10
12
14
13
15

Advertisement

loading

Summary of Contents for ABB IEC 60617

  • Page 1 — Quick Start Guide Relion® 630 series Display Default view can be selected from e.g. single line diagram (SLD), measurement, events Self-supervision and Ready-LED steady: OK, Ready-LED flashing: Internal Relay Fault (IRF), Start-LED steady: protection started, protection indicator LEDs Start-LED flashing: protection function blocked, Trip-LED: protection operated Programmable LEDs Can be programmed for alarming and indication with latching and/or flashing features in 3 colors Function buttons...
  • Page 2 You can change all settings in the same way. The most common function block names are described at the end Complete customer documentation is available in the product of this document. pages that can be accessed through abb.com/relion.
  • Page 3 The most common function blocks are listed below, please refer to the 620 series Technical Manual for the full list. The available function blocks varies depending on the selected IED and configuration used. Function IEC 61850 IEC 60617 Protection Three-phase non-directional overcurrent, low stage PHLPTOC 3I>...
  • Page 4 With regard to purchase orders, illustrations contained therein. Any reproduction, disclosure to third the agreed particulars shall prevail. ABB does not accept any responsibility parties or utilization of its contents – in whole or in parts – is forbidden whatsoever for potential errors or possible lack of information in this without prior written consent of ABB.

This manual is also suitable for:

Iec 61850Relion 630 series