Guide values for mains connection

The power cable must be dimensioned by a qualified person in accordance with national and local regulations. The mains
socket to which the machine is connected must be dimensioned for the same amperage as the machine's electrical
socket and extension cable, e.g. a 63 A electrical socket must be preceded by a 63 A fuse.
Engine - 15 kW
Nominal
Min. voltage
voltage from
at machine
power source
V
400
400
400
460
460
460
*The cable lenght is calculated with respect to a voltage drop of 20 V during operation. Type of power source and wiring
from power source to power outlet affects possible cable length.

The hydraulic system pressure

Type of pressure
Pump pressure
The pressure in the pipes between pump and main stop valve. The
pressure varies between standby pressure and max. pressure
depending on which hydraulic functions are being used.
Standby pressure*
* The pressure that the pump delivers when no function is activated and the circulation valve is shut.
Hydraulic fluid and lubricant
Hydraulic fluid
Quality
Mineral oil ISO VG32
Mineral oil ISO VG46 (Standard)
Mineral oil ISO VG68
Always ask the machine manufacturer before using a type of hydraulic fluid other than those mentioned above.
The quality of hydraulic fluid that the machine was supplied with is indicated on the sticker next to the filling pump.
NOTICE! The machine can be damaged if different types of hydraulic fluid are mixed. Check which quality of hydraulic
fluid the hydraulic system contains before refilling or changing.
Lubricant
Component
Oil gearbox drive motor
All lubrication points with grease nipples

TECHNICAL DATA

Cable area
2
V
mm
/AWG
380
4
380
6
380
10
440
4
440
6
440
10
Minimum starting
temperature, ° ° ° ° C/° ° ° ° F
-20/-4
-10/14
-5/23
Starting
Motor
current
output
A
75
50
75
Hz
75
75
60
75
Hz
75
Tool, max
Rotating function
Outrigger down/up
Arm functions
External hand tool
Max. temperature, ° ° ° ° C/° ° ° ° F
75/167
85/185
90/194
Quality
SAE 80W-90
NLGI 2
Setting
thermal
overload
relay
kW
A
15,0
27,0
15,0
27,0
15,0
27,0
15,0
24,0
15,0
24,0
15,0
24,0
50-250 (default 140)
temperature, ° ° ° ° C/° ° ° ° F
55-80/131-176
Max. cable
length*
m
177/581
266
444
200
300
500
Pressure, bar
250
180
250/130
200
20+/-1
Ideal working
35-60/95-140
45-70/13-158
Standard
API GL 5
English – 55