Technical data

General
Rotation speed, rpm
Transport speed max., km/h / mph
Angle of inclination, max.
Hydraulic system
Volume hydraulic system, l/gal
Pump type
Pump flow max.*, l/min / gal/min
Electric motor
Type
Power, kW
Speed, rpm
Voltage, V
Current, A
Control system
Control type
Signal transmission
Weight
Without tools and hydraulic oil, kg/lb
Tools
Rec. max. weight, kg / lb
*Maximum pump flow and system pressure cannot be taken out at the same time, the motor will be overloaded. 60 Hz has limited
displacement.
Noise emissions
Noise emissions in the environment measured as sound power (L
between the guaranteed and the measured noise level is a measurement of dispersion and variations in the declared value.
Machine without tool
Sound power level, measured dB (A)
Sound power level, guaranteed L
Machine with tool (hydraulic hammer)
Sound power level, measured dB (A)
Sound power level, guaranteed L
Sound level
Reported data for sound pressure level has a typical statistical dispersion (standard deviation) of 2 dB(A).
Sound level 10 m from the machine's tools*, dB(A)
* The stated value refers to work with a hydraulic hammer. Other types of recommended tools create a considerably lower noise
level.
54 –
English
TECHNICAL DATA
6
3/1,9
30°
50/13
Load sensing axial piston pump with variable displacement
65/17
Siemens 1LE1001-1DB73
22 (50 Hz)
24,5 (60 Hz)
1475 (50 Hz)
1775 (60 Hz)
380-420 (50 Hz)
440-480 (60 Hz)
40,5 (50 Hz)
38,5 (60 Hz)
Remote control
Bluetooth/cable
1960/4320
310/683
87
dB (A)
94
WA
118
dB (A)
118
WA
90
) in conformity with EC directive 2000/14/EC. The difference
WA

Hide quick links: