Siemens SIMATIC S7-1500 Manual page 23

Drive controller
Hide thumbs Also See for SIMATIC S7-1500:
Table of Contents

Advertisement

Product overview
2.3 Hardware properties
Properties
The SIMATIC Drive Controllers have the following properties:
Table 2- 3
Hardware properties
Properties
Supply voltage (X124)
PROFINET IO
PROFINET interface (X150
P1R, X150 P2R, X150 P3)
PROFINET interface (X160 P1)
PROFINET interface (X130 P1)
Operation of the CPU as
IO controller
I-device
PROFIBUS DP
PROFIBUS interface (X126)
Operation of the CPU as a DP
master
Isochronous mode
Additional interfaces
USB 3.0 (X125, X135)
DRIVE-CLiQ interfaces (X100
to X103)
22
Description
The 24 V DC supply voltage for the SIMATIC Drive
Controller is fed via a 4-pin cable connector located
on the front of the SIMATIC Drive Controller.
The interface has three ports. In addition to basic
PROFINET functionality, it also supports PROFINET
IO RT (Real-Time) and IRT (Isochronous Real-Time).
The interface can be operated isochronously with the
clock pulse system of SINAMICS Integrated and the
X142 technology I/Os.
The interface has one port. In addition to basic
PROFINET functionality, it also supports PROFINET
IO RT (Real-Time).
The interface has one port. It supports basic
PROFINET functionality.
IO controller:
As an IO controller the CPU controls the connect-
ed IO devices
I-device:
As an I-device (intelligent IO device) the CPU is
assigned to a higher-level IO controller and is
thereby used as an intelligent pre-processing unit
of sub-processes
The interface is used for connecting to a PROFIBUS
network.
As a DP master, the CPU addresses the connected
DP slaves. The CPU cannot be a DP slave.
The PROFIBUS interface can be operated isochro-
nously. However, isochronous coupling with the clock
pulse system of SINAMICS Integrated and the X142
technology I/Os is not possible.
No function assigned at present
The SIMATIC Drive Controller has four DRIVE-CLiQ
interfaces. For each DRIVE-CLiQ interface, you have
24 V/450 mA available for connecting encoders and
measuring systems.
Additional information
Section Connecting
(Page 43)
SIMATIC Drive Controller
system manual
(https://support.industry.siem
ens.com/cs/ww/en/view/1097
66665)
Section Connecting
(Page 43)
PROFINET function manual
(https://support.industry.siem
ens.com/cs/ww/en/view/4994
8856)
Section Connecting (Page 43)
PROFIBUS function manual
(https://support.industry.siemens
.com/cs/ww/en/view/59193579)
-
Section Connecting (Page 43)
SIMATIC Drive Controller
Equipment Manual, 11/2019, A5E46600370-AA

Advertisement