Version: SNA-EN-UM-1.0-05
SN:092.0004904
USER MANUAL
ECO Hybrid Inverter
SNA3000 WPV
SNA4000 WPV
SNA5000 WPV
Where sun shined
Power always on
Monitor APP Download
IOS
Android
LUX POWER TECHNOLOGY CO., LTD
www.luxpowertek.com
info@luxpowertek.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SNA5000WPV and is the answer not in the manual?

Questions and answers

Thiathu
March 24, 2025

what is the best setting for luxpower with the 3 pannels

1 comments:
Mr. Anderson
March 24, 2025

The Lux Power Technology SNA5000WPV inverter supports multiple PV input modes. For three panels, the best setting depends on their configuration. If they are connected as two independent strings, select "S" (two independent strings input) in the PV input mode settings. If all three panels are connected in a single string, select "P" (same string input for MPPTs). Ensure the MPPT voltage range (120V–385V) is met for optimal performance.

This answer is automatically generated

Summary of Contents for Lux Power Technology SNA5000WPV

  • Page 1 Version: SNA-EN-UM-1.0-05 SN:092.0004904 USER MANUAL ECO Hybrid Inverter SNA3000 WPV SNA4000 WPV SNA5000 WPV Where sun shined Power always on Monitor APP Download Android LUX POWER TECHNOLOGY CO., LTD www.luxpowertek.com info@luxpowertek.com...
  • Page 2: Table Of Contents

    Table Of Contents 3. Working Modes Information on this Manual Validity 3.1 Offgrid modes introduction Scope 3.2 Working modes related setting description 4. LCD Display and settings Target Group Safety Instructions 4.1 LED Display 4.2 LCD Display 1. Brief Introduction 4.3 Inverter Status Display 1.1 Features of the inverter 4.4 LCD Settings...
  • Page 3: Information On This Manual

    1. Brief Introduction Information on this Manual 1.1 Features of the inverter Validity This manual is valid for the following devices:SNA3000 WPV/SNA4000 WPV/SNA5000 WPV Luxpower View Internet Scope Wifi / 4G This manual provides the installation, operation and troubleshooting of this unit, please read this manual LOGIN carefully before installations and operations.
  • Page 4: Interface Of The Inverter

    1.2 Interface of the inverter 1.3 Packing List Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. You should have received the following items in the package: LCD display Cross Head Expansion Screw Function buttons ECO Hybrid inverter X1 User Manual X1 Wi-Fi Module X1...
  • Page 5: Installation

    The system connection is as below: Gauge Model Cable (mm2) Torque Value 600V, 2*10AWG 600V, 2*10AWG SNA5000WPV 10AWG 1.2 Nm QF 1 Grid AC Input 3. PV Connection: Please install separately a DC circuit breaker between inverter and PV modules.
  • Page 6: Mounting The Unit

    2.2 Mounting the Unit 2.3 Battery Connection Notice: Consider the following points before selecting where to install: 2.3.1 Battery Power Cable Connection Mount on a solid surface Note: for lead acid battery, the recommended charge current is 0.2C( C to battery capacity) Do not mount the inverter on flammable construction materials.
  • Page 7: Ac Input/Output Connection

    2.4 AC Input/Output Connection 2.5 PV Connection Please follow below steps to implement PV module connection: CAUTION!! 1. Remove insulation sleeve 10 mm for positive and negative conductors. - There are two terminal blocks with “IN” and “OUT” markings. Please do NOT mis-connect input and 2.
  • Page 8: Dry Contact Signal Control

    2.7 Dry Contact Signal control All lux units can work with generator. Users can connect the generator output to ECO Hybrid inverters. GEN input terminal. The Dry port(NO2,COM2,NC2) could be used to deliver signal to external device when battery voltage The generator will be automatically started when battery voltage is lower than the cut-off value or there is charge reaches warning level.
  • Page 9 Step3. Setup the monitor for the system, add all datalogs in one station. Users can login to the visit interface of Cannot share PV input monitor system, Configuration->station->Plant Management->add datalog to add the datalogs. at any time! Monitor Data Overview Maintain Aspergo User Center...
  • Page 10: Working Modes

    3. Working modes 3.1 ECO Hybrid inverter modes introduction: 1. AC charge the battery from AC Input or GEN Input AC Charge 2. When the battery is power off, Bypass Mode AC is used to take the load the AC can wake up the battery automatically PV+AC charge the battery PV charge the battery while the...
  • Page 11: Working Modes Related Setting Description

    3.2 Working Modes related setting description Working modes and Description Situation Setting 1 Setting 2 Setting 3 off grid inverter mode if P_Solar>=P_load, solar is used to take load and charge battery AC abnormal if P_Solar<P_load, solar and battery take the load together, system will discharge until battery lower than the Cut Off Voltage/SOC Hybrid Mode 1(charge first) Solar power will used to charge battery first,...
  • Page 12: Lcd Display And Settings

    1. SONAR can work as traditional off grid inverter or as a hybrid inverter. When disable PV&AC Discharge Setting Take load Jointly, it will work as a traditional off grid inverter, otherwise it will work as a hybrid Discharge Control According to SC Hybrid Setting Battery Warning Voltage...
  • Page 13: Lcd Display

    4.2 LCD Display 4.3 Inverter Status Display Normal status, running status 40 Warning Status, warning 29 Description Remarks Display the currently time/date by default(year/month/day/ hour/ minute” switching automatically). When press Up or Down buttons, Generally Information this area will display the firmware version information, serial number Display Area etc.
  • Page 14: Lcd Settings

    4.4 LCD Settings Run with No Battery: Step1:Choose battery type first, when no flashing, select Enter to choose Run with No battery For Lead Acid: Step1:Choose battery type first, when Lead-Acid flashing, select Enter to choose Lead-acid battery There are four buttons on the LCD. Step for settings by Step2:Then choose battery capacity Battery the display:...
  • Page 15 Setting range: VOLT: 40.0-OnGrid EOD Volt Setting range: Default: 42V ConChr: 50.0-59.0Vdc CutOFF: CV voltage setting Default: 56.4V Cut off Voltage (Only in Lead-acid or SOC, depend battery type) SOC: 0-OnGrid EOD SOC on TEOd Default: 15% Setting range: VOLT: Cut off Volt-56V Default: 42V Setting range: Eod:...
  • Page 16 AC charge setting Setting Range: (The setting process Feed-In Disable (default) AC Charge function: must enable the AC Disable(Default) Feed-In charging function, Enable Enable/disable confirm the full (Touch “Enter” button to Only valid when battery SOC value, set ac charge parameter ) Hybrid is enabled Feed-In Enable and set the...
  • Page 17 Setting Range: Setting Range:-200~200W Green Function Disable 20W (default) (default) Green Function CT Offset enable/disable Green Function Enable Setting Range: Fan1 Speed Percent ECO Mode Disable (default) ECO Mode Enable Setting Range: 20-100% 70% (default) Fan speed setting Fan1 Speed New Slope Parallel type setting Setting Range: Disable (default)
  • Page 18: Specifications

    Table 1 Line Mode Specifications The APP is also available in the google play and apple APP store(Scan two code bar to download the APP). INVERTER MODEL SNA5000WPV/SNA4000WPV/SNA3000WPV Please download the introduction of guidance by website: https://www.luxpowertek.com/download/ Input Voltage Waveform...
  • Page 19 (AC Charger Plus Solar Charger) Low DC Cut-off Return SOC Low DC Cut-off SOC +10% Table 4 General Specifications Charge Cut-off Voltage 58.4Vdc SNA5000WPV/SNA4000WPV/SNA3000WPV INVERTER MODEL No Load Power Consumption <60W Safety Certification Table 3 Charge Mode Specifications Operating Temperature Range 0°C to 50°C...
  • Page 20: Trouble Shooting & Error List

    7. Trouble Shooting & Error List The failures mainly divided into 5 categories, for each category, the behavior is different: Description Trouble shooting Description Trouble shooting Code Code Restart inverter, if the error still exist, contact us (DSP&M3) E000 Internal communication fault1 Check if you have choose the right battery brand and Communication failure communication cable is right, if the warning still exist,...