Advertisement

Quick Links

O PER ATIO N MA NUA L
TA514-SAFETY
AC500-S training case

Advertisement

Table of Contents
loading

Summary of Contents for ABB TA514-SAFETY

  • Page 1 — O PER ATIO N MA NUA L TA514-SAFETY AC500-S training case...
  • Page 2: Table Of Contents

    5.3. Accessories ................................10 6. Dimensions ..............................11 7. Getting started .............................. 12 7.1. How to remove TA514-SAFETY from the case ....................13 7.2. Power supply ................................ 13 7.3. Functionality - front panel ..........................15 8. Circuit diagrams ............................18 9.
  • Page 3: Disclaimer

    The user shall be solely responsible for the use of this AC500-S Training Case described within this file. ABB shall be under no warranty whatsoever. ABB's liability in connection with this application example or the files included within this file, irrespective of the legal ground, shall be excluded. The exclusion of lia- bil-ity shall not apply in the case of intention or gross negligence.
  • Page 4: Introduction

    The operational guidelines described below are information which relates to the device, place of actual use, transportation, storage, assembly, use and maintenance. This TA514-SAFETY Training Case has been designed for use in an industrial environment in compliance with the 2004/108/EC EMC Directive and 2006/95/EC Low Voltage Directive with the following harmo- nized standards: •...
  • Page 5: Before You Start

    TA- 5 14- S A FET Y AC 50 0 - S T R A I N I NG CA S E — 3. Before you start 3.1. Safety notices DANGER Indicates an imminent risk. It will lead to death or serious injury if not avoided. WARNING Indicates a possible risk.
  • Page 6: Definitions, Expressions, Abbreviations

    TA- 5 14- S A FET Y AC 50 0 - S T R A I N I NG CA S E 3.3. Definitions, expressions, abbreviations AC500-S ABB Safety PLC for applications up to SIL3 (IEC 61508 ed.2 and IEC 62061) and PLe (ISO 13849) Central Processing Unit Cyclic Redundancy Check.
  • Page 7: Product Overview

    In TA514-SAFETY, functional safety related diagnostic functions of the Safety PLC can be experienced as well as the main safety function of AC500-S Safety PLC e.g. to read safety digital and analog inputs and to control the safety digital outputs according to a user-defined IEC 61131 application program and con- figuration.
  • Page 8: Product Identification

    TA- 5 14- S A FET Y AC 50 0 - S T R A I N I NG CA S E 4.1. Product identification Information on product label (example) Description TA514-SAFETY Product type 1SAP182900R0001 Product part number 1494 1S1202500000000...
  • Page 9: Deliverables

    1. Compact size of the Training Case, easy to carry; 2. TA514-SAFETY System will be delivered in a case (L546 x W347 x H197mm) for safe transportation which is waterproof, resistant to chemicals, humidity and dust. The weight of case including the TA514-SAFETY setup will meet the limitations of hand luggage restrictions (max.
  • Page 10: Ac500/S500

    TA- 5 14- S A FET Y AC 50 0 - S T R A I N I NG CA S E AI581-S Safety analog input module AI581-S with 4 x02H safety current input channels 0..20 mA / 4..20 mA (up to SIL2 or PL d) or 2 safety current input channels (up to SIL3 or PL e).
  • Page 11: Dimensions

    TA- 5 14- S A FET Y AC 50 0 - S T R A I N I NG CA S E — 6. Dimensions TA514-SAFETY: TA514-SAFETY Training Case will be delivered in a case (L546 x W347 x H197 mm). The Training Case setup itself has following dimensions: DOCUMENT ID. REV.
  • Page 12: Getting Started

    3ADR025003M99*: “Regulations Concerning the Setting up of Installations AC500 Control Sys- tem, AC500-S Safety PLC” 2. 3ADR025091M*: AC500-S Safety User Manual 3. Exemplary Automation Builder project for TA514-SAFETY: TA514-SAFETY Training Case Project at http://www.abb.com/PLC NOTICE To edit the provided application program for TA514-SAFETY, the following Software is needed: •...
  • Page 13: How To Remove Ta514-Safety From The Case

    TA- 5 14- S A FET Y AC 50 0 - S T R A I N I NG CA S E 7.1. How to remove TA514-SAFETY from the case Following picture demonstrates the holding positions (see arrows) to remove TA514-SAFETY from the carrying case.
  • Page 14 TA- 5 14- S A FET Y AC 50 0 - S T R A I N I NG CA S E WARNING AC500-S Training Case is only intended to be used by skilled persons aware of the risks using electrical equipment and knowing the technical rules, codes and relevant standards. WARNING This Training Case must only be used with the delivered power supply adapter.
  • Page 15: Functionality - Front Panel

    TA- 5 14- S A FET Y AC 50 0 - S T R A I N I NG CA S E 7.3. Functionality - front panel Name Functionality (see circuit diagrams and AC500-S training applica- tion project for detail) Main power On/Off Control switch to power on/off the 24V DC power of TA514- switch...
  • Page 16 Press power “ON” switch and wait till CPUs (PM573 and SM560-S) have completed their boot se- quence. Use a programming cable (e.g. Ethernet cable) and connect it to the Ethernet interface of the CPU PM573. 4. Program the PLC with ABB Automation Builder software, which is available from: http://www.abb.com/PLC PAGE REV.
  • Page 17 TA- 5 14- S A FET Y AC 50 0 - S T R A I N I NG CA S E NOTICE For information on how to place or remove AC500/AC500-S modules please refer to Installation Instructions of AC500/AC500-S modules at http://www.abb.com/PLC. WARNING Hot plug and hot swap of energized modules is not permitted. All power sources (supply and process voltages) must be switched off while working on any AC500 system, including Safety Modules.
  • Page 18: Circuit Diagrams

    TA- 5 14- S A FET Y AC 50 0 - S T R A I N I NG CA S E — 8. Circuit diagrams PAGE REV. LANG. DATE DOCUMENT ID. 18/31 en_US 2021/09/15 3ADR025217M6801...
  • Page 19: Environmentally Friendly Disposal

    — 9. Environmentally friendly disposal All AC500/AC500-S components from ABB are designed with a minimal environment pollution effect. To enable environmentally friendly disposal of TA514-SAFETY components, they can be partially disassem- bled to separate various components from each other. Disposal of those materials shall be done in ac- cordance with applicable national and international laws.
  • Page 20: Attachment

    TA- 5 14- S A FET Y AC 50 0 - S T R A I N I NG CA S E — 10. Attachment Wiring diagram for TA514-Safety. WARNING Maintenance of AC500-S Training Case is only allowed by skilled persons aware of the risks of electrical equipment and knowing the technical rules, codes and relevant standards.
  • Page 21 TA- 5 14- S A FET Y AC 50 0 - S T R A I N I NG CA S E DOCUMENT ID. REV. LANG. DATE PAGE 3ADR025217M6801 en_US 2021/09/15 21/31...
  • Page 22 TA- 5 14- S A FET Y AC 50 0 - S T R A I N I NG CA S E PAGE REV. LANG. DATE DOCUMENT ID. 22/31 en_US 2021/09/15 3ADR025217M6801...
  • Page 23 TA- 5 14- S A FET Y AC 50 0 - S T R A I N I NG CA S E DOCUMENT ID. REV. LANG. DATE PAGE 3ADR025217M6801 en_US 2021/09/15 23/31...
  • Page 24 TA- 5 14- S A FET Y AC 50 0 - S T R A I N I NG CA S E PAGE REV. LANG. DATE DOCUMENT ID. 24/31 en_US 2021/09/15 3ADR025217M6801...
  • Page 25 TA- 5 14- S A FET Y AC 50 0 - S T R A I N I NG CA S E DOCUMENT ID. REV. LANG. DATE PAGE 3ADR025217M6801 en_US 2021/09/15 25/31...
  • Page 26 TA- 5 14- S A FET Y AC 50 0 - S T R A I N I NG CA S E PAGE REV. LANG. DATE DOCUMENT ID. 26/31 en_US 2021/09/15 3ADR025217M6801...
  • Page 27 TA- 5 14- S A FET Y AC 50 0 - S T R A I N I NG CA S E DOCUMENT ID. REV. LANG. DATE PAGE 3ADR025217M6801 en_US 2021/09/15 27/31...
  • Page 28 TA- 5 14- S A FET Y AC 50 0 - S T R A I N I NG CA S E PAGE REV. LANG. DATE DOCUMENT ID. 28/31 en_US 2021/09/15 3ADR025217M6801...
  • Page 29 TA- 5 14- S A FET Y AC 50 0 - S T R A I N I NG CA S E DOCUMENT ID. REV. LANG. DATE PAGE 3ADR025217M6801 en_US 2021/09/15 29/31...
  • Page 31 Fax: +49 62 21 701 1382 prevail. ABB AG does not accept any respon- contents – in whole or in parts – is forbid- Mail: plc.support@de.abb.com...

This manual is also suitable for:

Ac500-s

Table of Contents