Advertisement

Quick Links

Instructions for Assembly, Testing, Operation, Servicing, and Storage
Soft wash kit with bleach pump: For building a soft wash sprayer with tank for
READ and UNDERSTAND this Owner's Manual completely before using this sprayer.
Assemble, test, and use only in accordance with this Owner's Manual instructions.
EXERCISE CAUTION when mixing chemicals as incorrect ratios or mixtures could release
harmful gases.
READ and FOLLOW chemical label instructions.
KNOW emergency procedures BEFORE handling chemicals. Sprayer leaks, bodily chemical
contact, poisoning, and spills require immediate response.
AVOID inhaling, ingesting, or coming into contact with any chemicals.
WEAR personal protective gear when filling, using, cleaning, and servicing the sprayer.
KEEP sprayer and spray materials away from children and pets. Some chemicals are especially
toxic to them.
DO NOT TURN ON POWER to sprayer until ready to spray in order to avoid unintentional
spray release.
SOAK vegetation in the area surrounding the work zone well prior to and after spraying bleach.
Bleach can kill vegetation if not rinsed thoroughly.
ALWAYS keep a fire extinguisher rated "ABC" nearby.
Improper use of the sprayer or handling of chemicals could result in serious injury or illness
to the operator or nearby persons/animals or could cause damage to the environment.
**This sprayer is recommended for use in spraying bleach. The sprayer will be damaged, and warranty voided if used to apply
any petroleum-based product (gasoline, diesel, kerosene, or oil). The sprayer should not be used to transfer any product intended
for human consumption. WE RECOMMEND THAT THE SPRAYER NOT BE USED FOR OTHER PURPOSES ONCE IT HAS
BEEN USED FOR SPRAYING BLEACH. Any chemical will leave some residual in the tank liner or sprayer components, even
after the sprayer has been properly cleaned. These residual chemicals can have unexpected effects on future uses. This sprayer
should not be used by people with reduced physical, sensory or mental capabilities or lack of experience and knowledge.
Any Questions, Comments, Problems, or Parts Orders
Call NorthStar Product Support at 1-800-270-0810
Owner's Manual
outdoor use with bleach**
WARNING
M1572210B
ITEM NUMBER: 1572210, 1572212,
1572213
SERIAL NUMBER: _____________

Advertisement

Table of Contents
loading

Summary of Contents for NorthStar 1572210

  • Page 1 These residual chemicals can have unexpected effects on future uses. This sprayer should not be used by people with reduced physical, sensory or mental capabilities or lack of experience and knowledge. Any Questions, Comments, Problems, or Parts Orders Call NorthStar Product Support at 1-800-270-0810...
  • Page 2 Hazard Signal Word Definitions...
  • Page 3: Table Of Contents

    Table of Contents Intended Use .............................. 4 Summary of Important Safety Information ..................5-6 During Assembly During Operation • General Chemical Safety • Chemical Application Safety • Chemical Accident Procedures Warning Label Locations ........................... 7 Component Inventory Unpacking the Manual Bag ........................ 8-10 Assembly ...............................
  • Page 4: Intended Use

    (gasoline, diesel, kerosene, or oil). NOTICE: Not for use on painted wood surfaces. Use only on hard, non-porous surfaces. Contact NorthStar Product Support at 1-800-270-0810 for any questions about the appropriate use of the sprayer and/or optional accessories.
  • Page 5: Summary Of Important Safety Information

    Summary of Important Safety Information WARNING Read and understand this owner's manual completely before using the sprayer. Read each chemical label's instructions before handling the chemical. Improper use of the sprayer or handling of chemicals could result in serious injury or illness for the operator or nearby persons/animals, or cause damage to the environment.
  • Page 6: Chemical Accident Procedures

    Summary of Important Safety Information (continued) • CLEAN up spills immediately per instructions on chemical labels. • TURN OFF power to sprayer and RELIEVE system pressure before leaving sprayer unattended. • SEE Troubleshooting section of this manual before attempting any repairs. Wear personal protective equipment and follow safety instructions.
  • Page 7: Warning Label Locations

    Always make sure safety labels are in place and in good condition. If a safety label is missing or not legible, order new labels or unsafe operation could result. To order replacement safety labels, call NorthStar Product Support at: 1-800-270-0810.
  • Page 8: Unpacking The Manual Bag

    Unpacking the Manual Bag The following items are found in the 1572210 manual bag. Fitting, QC x 1/2” HB, straight Fitting, QC x 1/2” HB, elbow 787193 787197 (Qty 2) (Qty 1) Inlet strainer 798855 (Qty 1) Hose clamp Screw, #10-24 x 1-1/4”...
  • Page 9 Unpacking the Manual Bag The following items are found in the 1572212 manual bag. Fitting, QC x 5/8” HB, straight Fitting, QC x 5/8” HB, elbow 801591 799878 Inlet strainer (Qty 2) (Qty 1) 798855 (Qty 1) Hose clamp Screw, #10-24 x 1-1/4” 793231 802176 (Qty 3)
  • Page 10 Unpacking the Manual Bag The following items are found in the 1572213 manual bag. Fitting, QC x 5/8” HB, elbow Fitting, QC x 5/8” HB, straight 799878 801591 Inlet strainer (Qty 1) (Qty 2) 798855 (Qty 1) Hose clamp Screw, #10-24 x 1-1/4” 793231 802176 (Qty 3)
  • Page 11: Assembly

    Assembly Step One: Mounting • This NorthStar pump is self-priming. • The pump should be located in an area that is dry and provides adequate ventilation. CAUTION DO NOT locate the motor near low temperature plastics or combustible material. The surface temperature of the motor may exceed 250°F [121°C].
  • Page 12 • The pump is protected with a fuse. Use an approved wire of the size specified or heavier. Fuse Type Voltage Model Fuse (amp) 12V DC 1572210 15.0 Mini blade 12V DC 1572212 15.0 Mini blade 12V DC 1572213 20.0 Mini blade 3.
  • Page 13 Assembly 4. Verify connection Verify a complete connection has been made by checking with a DC voltmeter, or by briefly turning the ON/OFF switch on the pump and on the wire harness to the ON position and listening for pump activation. 5.
  • Page 14: Features

    Features 1. Motor Armor System. This system will shut the pump off in the event of a leak inside the pump cartridge to prevent damage to the motor. 2. ON/OFF Switch. Allows the operator to turn the pump on and off. 3.
  • Page 15: Important Safety Information - Operation

    Operation – Important Safety Information Now that you have completed and tested your assembly, there is some important safety and health information you need to know with regard to handling and spraying chemicals. WARNING Carefully read and make sure you understand the following safety information before using the sprayer.
  • Page 16: Chemical Application Safety

    Operation – Important Safety Information (continued) Chemical Application Safety: WARNING • Caution must be used when spraying chemicals to avoid unsafe exposure to humans and the environment • Heed the warnings below and follow all instructions carefully. Before Spraying • Soak.
  • Page 17: Chemical Accident Procedures

    Operation – Important Safety Information (continued) Chemical accident procedures: WARNING Before you fill the sprayer, review the following information with regard to handling accidents. Chemical spills, sprayer leaks, personal contamination, and poisoning are accident situations which you may encounter. All require an immediate response –...
  • Page 18 Operation – Important Safety Information (continued) Chemical spills Chemical spills must be quickly contained and properly cleaned up. Refer to the chemical label for any specific clean-up instructions with regard to the chemical spilled. General procedures include: 1. Control the spill by stopping the source of the spill. If the source of the spill is a container leak, place the leaking container in a larger, watertight container.
  • Page 19: Preparing The Sprayer For Each Use

    Inspect hoses for exposed mesh and holes. Replace all worn or damaged hoses. b) Inspect fittings for cracks and leaks. Replace all damaged fittings with original NorthStar parts. c) Partially fill tank with plain water and spray to test for leaks. Repair as needed.
  • Page 20: Step One: Assess Wind Conditions And Clear Work Area

    Operation – Using the Sprayer Step 1: Assess wind conditions and clear work area. Before you decide to spray, you must determine whether wind conditions are suitable. You must also restrict access to the work area to ensure the safety of bystanders. WARNING Do not spray if wind speeds are greater than 5 MPH or if there are bystanders in the intended spray area.
  • Page 21: Step Two: Mixing Chemicals

    6 gallons concrete, driveways NOTICE: Never spray undiluted bleach. It must be mixed with water and NorthStar Max Cling Soft Wash Surfactant. Failure to do so could result in unforeseen damage to vegetation or the cleaning surface. Always test soft wash mix in an inconspicuous area to confirm compatibility.
  • Page 22: Step Three: Operate The Sprayer

    4. Selecting nozzle 1572210 and 1572212 come with two nozzles to select from: fan tip and long-throw. 1572213 comes with four nozzles to select from: 25°, 40°, 60° fan tip and one long- throw.
  • Page 23 Follow the steps below for spraying a roof: with soft wash 1. Using a 3% mix (see table), spray roofs from top to bottom. Soft Wash Mix Household Bleach NorthStar Max Cling Water 6 gallons 8 ounces 6 gallons 2. Spray in 10-foot-wide sections, only applying enough to get the surface wet.
  • Page 24 Operation - Using the Sprayer (continued) 8. Rinsing After spraying rinse all surfaces and vegetation 1. Using fresh water from a garden hose, rinse any vegetation that may have come into contact with soft wash mix. 2. Rinse surfaces from top to bottom. Rinse until there are no visible suds on the cleaned surface.
  • Page 25: Step Four: Clean Sprayer And Decontaminate After Use

    Operation - Using the Sprayer (continued) Step 4: Clean sprayer and decontaminate after use. When finished using the sprayer, it is important to clean the sprayer and decontaminate yourself. Do not store the sprayer with chemicals in the tank, as it is unsafe and could also result in damage to the equipment.
  • Page 26: Storage

    Storage When not in use, store indoors. For long term or winter storage, prepare by running RV antifreeze (DO NOT USE automotive antifreeze) through the system. This will keep internal parts lubricated, protect against corrosion, and keep the unit from freezing. CAUTION •...
  • Page 27: Troubleshooting

    Troubleshooting WARNING Before troubleshooting or attempting to service, read the following safety rules to avoid accidental exposure to chemical and also risk of electric shock. Note: A reserve, clean container should be kept for use when the sprayer tank needs to be emptied temporarily for repairs.
  • Page 28: Maintenance

    In the event of an internal pump cartridge leak, the pump will shut off to protect the motor and the LED light will turn on to indicate the problem. To repair the pump, use the replacement pump cartridge number corresponding with the model number. Model number 1572210 1572212 1572213 Pump Cartridge Number...
  • Page 29: Specifications

    The manufacturer reserves the right to make improvements in design and/or changes in specifications at any time without incurring any obligation to install them on units previously sold. Any Questions, Comments, Problems, or Parts Orders Call NorthStar Product Support at 1-800-270-0810...
  • Page 30: Exploded View And Parts Breakdown

    1572210 799940 Nozzle, straight stream, #40 orifice 1572212 801859 Nozzle, straight stream, #60 orifice 1572213 157145 NorthStar pump w/ motor armor, 2.2gpm 1572210 157147 NorthStar pump w/ motor armor, 4.0gpm 1572212 157153 NorthStar pump w/ motor armor, 5.5gpm 1572213 799883...
  • Page 31: Pump Exploded View

    Pump Exploded View - 1572210 Ref # Part # Description 802275 Motor Assembly A157145 Pump Cartridge 800428 Base Plate Assembly 784449 Quick Connect Clip, Black 800088 Decal, Pump Branding 787381 Replacement Fuse, 15A...
  • Page 32 Pump Exploded View – 1572212 & 1572213 Ref # Part # Description Model 802274 1572212 Motor Assembly 802273 1572213 A157147 1572212 Pump Cartridge A157153 1572213 800428 Base Plate Assembly 784449 Quick Connect Clip, Black 800090 1572212 Decal, Pump Branding 800092 1572213 787381 Replacement Fuse, 15A...
  • Page 33: Limited Warranty

    NorthStar shall warranty any wear item to be free from defects in material or workmanship for a period of 90 days from the date of purchase by user. This warranty applies to the original purchaser of the equipment and is non- transferable.
  • Page 34 Manufactured by Northern Tool & Equipment Company, Inc. Burnsville, Minnesota 55306 www.northerntool.com Made in China...

This manual is also suitable for:

15722121572213

Table of Contents