Technical Data; Qwik-Pure ® Operating Parameters; Storage Parameters - Beko QWIK-PURE 10 Installation And Operation Manual

Table of Contents

Advertisement

Installation and operation manual

4. Technical data

4.1 QWIK‑PURE
®
Parameter
Relative ambient air humidity
Maximum operating altitude above sea level
Maximum operating pressure at condensate inlet
Minimum / maximum operating temperature, fluids 
and environment
Maximum condensate flow rate
Connection, condensate inlet
Connection, condensate drain
Media
Maximum operating weight
Maximum oil concentration at condensate drain port

4.2 Storage parameters

Parameter
Minimum / maximum temperature
Relative ambient air humidity
Empty weight
operating parameters
QWIK‑PURE
≤10 ... 80 %, without condensation
2000 m
2187.23 yd
16 bar(g)
230 psi(g)
+5 ... +50 °C
+41 ... +122 °F
12.7 l/h
3.36 gal/h
3 x G1/2", male
1 x G1", male
Hose connection
1 x 23 mm (0.91 in), male
Hose connection
Compressor condensate, oil-contaminated
50 kg
110.2 lbs
20 mg/l
20 ppm
QWIK‑PURE
+5 °C ... +50 °C (+33.8 °F ... +122 °F)
≤10 ... 80 %, without condensation
13.5 kg
29.8 lbs
QWIK-PURE
®
10
®
10
®
19 | 64