Installation and operation manual
3.2 Function description
The condensate is fed from the condensate collection line via the condensate inlet [A] into the pressure relief
chamber [1]. In the pressure relief chamber [1], entrained compressed air is separated before the condensate
flows through the connecting pipe [3] into the filter cartridge [10].
The condensate flows through the filter cartridge [10] into the collector [8].
The purified condensate is fed from the collector [8] via the riser duct [9] into the clean water tank [4]. The
purified condensate is conveyed into the wastewater connection through the condensate drain [B] of the
clean water tank [4] .
If the filter cartridge [10] is saturated with oil, the filter cartridge [10] will need to be replaced (see section
"9.3.2 Replacing filter cartridges" on page 42).
A level indicator [12] is integrated into the pressure relief chamber [1]. If the filling level in the pressure relief
chamber [1] rises as a result of impaired condensate flow (see section "14. Troubleshooting" on page 62),
the level indicator [12] will be pushed up so that the red marking on the level indicator [12] will become
visible.
A
1
3
B
4
9
8
QWIK-PURE
10
®
15 | 64