Check Startaddr Endaddr Count; Save Startaddr Endaddr [Progstartaddr] - Fujitsu F2MC-16L Series User Manual

Hide thumbs Also See for F2MC-16L Series:
Table of Contents

Advertisement

CHECK S
3.5.19.
Examine memory area
Checks the memory area specified by StartAddr and EndAddr. The write and read back test is
proceeded Count times.
>check 84000 8ffff 4↵
NOTE: The memory area is completely overwritten after this operation. Do not check areas
containing valid data.
CONVERT V
3.5.20.
Print value in various number formats
The CONVERT command can be used to print a different representation of a value.
For example, if a hex number is specified as operand value, the decimal and binary equivalents
are printed.
>convert 777↵
SAVE S
3.5.21.
Generate a hex record dump
This command dumps the specified memory area formatted as HEX- or S-record lines. This
might be used for saving smaller areas in order to re-load them in a later session. The records
are output to the terminal without any protocol. It should be stored using the ability of most
terminal programs to create a LOG-file. Further hints are given on use.
ProgStartAddr is a possible program start address coded in special record lines. It is
transferred to the PCB and PC register when it is re-loaded. Note, that the record format can
be changed with the HEXFORMAT command.
>save 80000 81fff↵
© FUJITSU Mikroelektronik GmbH 1996
FUJITSU MB90675-Evaluation Board - User Manual
A
TART
DDR
ALUE
A
TART
DDR
E
A
C
ND
DDR
OUNT
E
A
[ P
ND
DDR
ROG
S
A
]
TART
DDR
- 33 -