5.2.3

Features

Table 5.1 lists the features for a three-phase 9960 subsystem.
Table 5.1
9960 Three-Phase Features
Frame
Feature Number
Controller
N/A
Disk Array
DKU-F405I-3PS
Disk Array
DKU-F405I-3EC
Disk Array
DKU-F405I-3UC
5.2.4

Current Rating, Power Plug, Receptacle, and Connector for Three-Phase (60 Hz only)

Table 5.2 lists the current rating and power plug, receptacle, and connector requirements
for three-phase 60-Hz 9960 subsystems. In a three-phase 9960 subsystem the controller
frame (DKC) receives its AC input power from the first disk array frame (DKU) via internal
cabling, so that subsystem will not require any customer outlets for the controller frame.
The user must supply all power receptacles and connectors for both 60-Hz and 50-Hz
subsystems. Russell & Stoll type (R&S) connectors are recommended for 60-Hz systems.
Note: Each disk array frame requires two power connections to ensure power redundancy. It
is strongly recommended that the second power source be supplied from a separate power
boundary to eliminate source power as a possible single (nonredundant) point of failure.
Table 5.2
Current Rating, Power Plug, Receptacle, and Connector for Three-Phase 9960
Item
Hitachi Base Unit
Circuit Current Rating
Hitachi Feature(s) Required
60-Hz Power Plug (or equiv.)
Included with the product.
Box-Type Receptacle (or equiv.) (not provided)
Inline Connector (or equiv.) (not provided)
*Note: For information on power connection specifications for locations outside the U.S.,
contact the Hitachi Data Systems Support Center for the specific country.
84
Chapter 5 Planning for Installation and Operation
Description
AC Box Kit for Three-Phase
Power Cable Kit (Three-Phase Model for Europe)
Power Cable Kit (Three-Phase Model for USA)
9960 DKC
9960 DKU
DKC410I-5
DKU405I-14
(from DKU)
30 A
none
DKU-F405I-3PS
DKU-F405I-3UC
N/A
R&S 3760PDG/1100
N/A
R&S 3754
N/A
R&S 3934
Comments
If using three-phase power, the
Controller Frame receives its input
power from the first disk array frame. All
Controller single-phase features must be
removed to allow three-phase power for
the Controller.
Consists of two AC Boxes

Hide quick links: