PDH / DSn Testing With The HP 37717C
BERT Testing
The total graphics store capacity is normally 20,000 events. If GRAPH STORAGE
RESOLUTION [FULL] is selected on the
OTHER
display
MISCELLANEOUS
the capacity reduces to 10,000 events.
The resolution, determined by the selection made under STORAGE on the
display, affects the ZOOM capability when
TIMING CONTROL
RESULTS
viewing the bar graphs. If 1 SECOND is selected all resolutions are available under
ZOOM. If 1 MIN is selected only 1 MIN/BAR, 15 MINS/BAR and 60 MINS/BAR
are available.If 15 MINS is selected only 15 MINS/BAR and 60 MINS/BAR are
available. If 1 HOUR is selected only 60 MINS/BAR is available.
Up to 10 sets of graphical results can be stored. If an attempt is made to store more
than 10 sets of results, then a first in first out policy is operated and the oldest set of
results will be lost. If graphics are enabled and a test is run which exceeds the
remaining storage capacity, then some previously stored graphical results will be
lost.
To prevent accidental overwriting of previously stored results the graphics capability
should be disabled, when graphical results are not required, by selecting STORAGE
[OFF] on the
display.
TIMING CONTROL
RESULTS
37