SPECIFICATIONS

Heads
Type
Item
Model No.
CE marking directive compliance
Effective charge removal width
50 mm
Charge removal time
0.3 sec. or less (Note 1),
(±1,000 V→±100 V)
0.5 sec. or less (Note 2)
Ion balance
Discharge method
Discharge frequency
Discharge output voltage
Ozone generation
Maximum air pressure
Applicable fluid
Operating altitude
0 to +50 °C
Ambient temperature
Ambient humidity
10 to 55 Hz (ER-X001: 10 to 150 Hz) frequency, 0.75 mm
Vibration resistance
Shock resistance
Enclosure grounding method
Main unit enclosure: PPS, Stainless steal (SUS), Head mounting bracket: Stainless steal (SUS), Discharge needle: PC, PPS, Tungsten (Note 7)
Material
[ER-X001 – Main unit enclosure: Stainless steel (SUS), Head mounting bracket: Stainless steel (SUS), Discharge needle: PFA, Tungsten]
Length of high-voltage cable
Net weight
Accessory
Type
Item
Model No.
CE marking directive compliance
Effective charge removal width 80 mm
Charge removal time
(±1,000 V→±100 V)
Ion balance
Discharge method
Discharge frequency
Discharge output voltage
Ozone generation
Maximum air pressure
Applicable fluid
Operating altitude
Head: -60 to +200 °C
Ambient temperature
High voltage unit: 0 to +50 °C
Ambient humidity
Vibration resistance
Shock resistance
Enclosure grounding method
Material
Length of high-voltage cable
Net weight
Accessories
Notes: 1) Typical value in condition of discharge distance 50 mm
2) Typical value in condition of discharge distance 100 mm
3) Ion balance refers to the average value of plus and minus. The specification value is the typical one in condition used when ambient temperature
change is less than ±10 °C, ion balance is set after 30 minutes from the discharge start, the ion balance control function is set ON.
4) The high-voltage cable is also available in lengths of 1 m
30 / 20 / 10 / 5 / 1 Hz. For details, please contact our sales office.
5) The dried clean air is the air dried (dew point: equivalent of -20 °C
6) Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
7) Silicon needles (ER-X016S, ER-X032S and ER-XANS) are also available. For details, please contact our sales office.
8) Set the discharge frequency to 30 Hz. Do not use any other frequency.
9) Discoloration of the head may occur when used under high temperatures, but it does not affect the charge removal performance.
Spot type
ER-X001
ER-X008
1.969 in
approx.
80 mm
3.150 in
approx.
50 Hz / 30 Hz / 20 Hz
50 Hz / 20 Hz
/ 10 Hz / 5 Hz / 1 Hz
+32 to +122 °F
(ER-X001: 0 to +40 °C
2
100 m/s
acceleration (10 G approx.), in X, Y and Z directions three times each
1.2 m
3.937 ft
0.5 m
1.640 ft
370 g approx.
330 g approx.
ER-X008HC
ER-X016HC
3.150 in
approx.
160 mm
6.299 in
-76 to +392 °F
(No dew condensation or icing allowed) (Note 9), Storage: -10 to +65 °C
+32 to +122 °F
10 to 55 Hz frequency, 0.75 mm
2
acceleration (10 G approx.), in X, Y and Z directions three times each
100 m/s
Main unit enclosure: PPS, Stainless steal (SUS), Head mounting bracket: Stainless steal (SUS),
Discharge needle: PC, PPS, Tungsten, Main unit enclosure of high-voltage unit: ABS
Heat-resistant shielded cable, 1.8 m
420 g approx.
490 g approx.
ø6 ø0.236-4 air tube joint: 1 pc., Seal cap: 1 pc., Head mounting bracket (mounted at the factory)
1.969
in, center of the product, discharge frequency 50 Hz and air supply 60 ℓ/min.(0.3 MPa).
3.937 in
(ER-X001: 50 mm
3.281 ft
Bar type
ER-X016
ER-X032
EMC Directive, RoHS Directive
160 mm
6.299 in
approx. 320 mm
12.598 in
1 sec. or less (Note 2)
±30 V or less (Note 2, 3)
Pulse AC method
100 Hz / 70 Hz / 50 Hz / 30 Hz / 20 Hz / 10 Hz / 5 Hz / 1 Hz (Note 4)
±7,000 V approx.
0.01 ppm or less (Note 2)
0.5 MPa
Air (dried clean air) (Note 5)
2,000 m
6561.68 ft
or less (Note 6)
+32 to +104
°F) (No dew condensation allowed), Storage: -10 to +65 °C
35 to 65 % RH, Storage: 35 to 85 % RH
0.030 in
double amplitude in X, Y and Z directions for two hours each
Floating
0.5 m
410 g approx.
530 g approx.
Head mounting bracket (mounted at the factory)
High and low temperature resistant
ER-X032HC
EMC Directive, RoHS Directive
approx.
320 mm
12.598 in
approx. 480 mm
1 sec. or less (Note 2)
±30 V or less (Note 2, 3)
Pulse AC method
30 Hz (Note 8)
±7,000 V approx.
0.01 ppm or less (Note 2)
0.1 MPa
Air (dried clean air) (Note 5)
2,000 m
6561.68 ft
or less (Note 6)
(No dew condensation allowed), Storage: -10 to +65 °C
35 to 65 % RH, Storage: 35 to 85 % RH
0.030 in
double amplitude in X, Y and Z directions for two hours each
Floating
5.906 ft
620 g approx.
1.969
in), center of the product, discharge frequency 50 Hz (ER-X□HC: 30 Hz) and no air supply.
and 2 m
6.562
ft. The discharge frequency of 1 m
-4
°F) and filtered (mesh-size: equivalent of 0.01 μm).
ER-X
SERIES
Area Ionizer
ER-X048
ER-X064
approx. 480 mm
18.898 in
approx. 640 mm
25.197 in
+14 to +149 °F
1.640 ft
(Note 4)
650 g approx.
780 g approx.
ER-X048HC
ER-X064HC
18.898 in
approx. 640 mm
25.197 in
+14 to +149 °F
+14 to +149 °F
long
760 g approx.
900 g approx.
3.281 ft
/ 2 m
6.562 ft
cables is 50 /
9
approx.
approx.

Advertisement