Download Print this page

Panasonic ER-X Series Manual page 3

Area ionizer
Hide thumbs Also See for ER-X Series:

Advertisement

Pulse AC method for faster charge removal
The ER-X series has adopted the pulse AC method
that alternately applies positive and negative voltages
to each discharge needle. This enables generation and
discharge of a large amount of ions, resulting in faster
charge removal. Select from eight pulse frequencies
according to your application, from 100 Hz for charge
removal on nearby or moving workpieces to 1 Hz for
charge removal on far-away workpieces or in a three-
dimensional space.
Charge removal time characteristics (TYPICAL)
Measured at a charge removal distance of 100 mm
a 150 × 150 mm
5.906 × 5.906 in
1,000
Conventional model, with airflow, 0.05 MPa
ER-X032, airless
800
ER-X032, with airflow, 0.05 MPa
600
Conventional model
400
ER-X
200
0
1
Charge removal time (sec.)
SPOT TYPE HEAD
ER-X001
Effective charge removal width:
50 mm
1.969 in
approx.
Supports airless and low-pressure charge
removal, which means charge removal is
possible without blowing away tiny work pieces
Free head placement is possible thanks to
flexible cable with internal air tube
3.937 in
using
CPM (at center of CPM).
2
3
4
Automatic ion balance control
The ER-X series provides an automatic ion balance
control mechanism that senses the amount of ions being
generated (which changes according to environmental
factors) and compensate for this deviation in the
controller, thus maintaining a highly stable ion balance
as an original operator setting.
<Pulse AC method>
Positive ion generation
Negative ion generation
Variable ion balance
0.3 sec. or less*
fastest charge removal achieved
1
with pulse AC method spot type ionizer*
The pulse AC method enables the ER-X001 to generate
and discharge a large amount of ions, which makes
charge removal faster. Furthermore, as a spot type
ionizer, it achieves the fastest charge removal of 0.3 sec.
or less*
(±1,000 V → ±100 V).
1
*1: As of March 2016, in-company survey
*2: Spot diameter of ø15 mm
ø0.591 in
Air supply port angle can be adjusted
ER-X001 high-voltage unit
Joint for ø6 mm
360°
ER-X
SERIES
Area Ionizer
Example of variable discharge
frequency/ion balance
2
or less
ø0.236 in
air tube
angle adjustment
3

Advertisement

loading