SECTION TWO: Installing and wiring the radar
Thickness of
mounting base
0.04-0.16 in. (1 - 4mm)
0.16-0.35 in. (4 - 9mm)
0.35-0.55 in. (9 -14mm)
0.55-0.75 in. (14 -19mm)
Arrows

Installing the control box

For the control-box dimensional drawing, see Figure 17 on page 29.
Do not install the control box in the bilge or areas with high level of humidity. The control box is not
waterproof.
Replacing the fuse
You must use proper rating fuses to safely operate the radar control box. Fuses marked with an
asterisk (
) in the following tables are installed in the set when shipped.
TABLE 5: Fuse requirements for MDS-5 (with 4 kW radome)
Supply voltage
12 VDC
24 VDC
Page 8
TABLE 4: Bolts for mounting open array antenna
Open array mounting bolts
M12 × 45 (1.5mm pitch)
M12 × 50 (1.5mm pitch)
M12 × 55 (1.5mm pitch)
M12 × 60 (1.5mm pitch)
Main fuse
8A/250V or 125V
(6.3Ø x 32mm)
8A/250V or 125V (6.3Ø x 32mm)
Material
Stainless
Stainless
Stainless
Included
Stainless
Antenna
radiation
surface
Figure 8: Attaching the array
Motor fuse
T3.15A/250V or 125V
T3.15A/250V or 125V (5Ø x 20mm)
Ethernet Radar Installation Manual, Rev. A
Comments
(5Ø x 20mm)

Advertisement

Table of Contents
loading

This manual is also suitable for:

972