 Pull the side runners out of holder (1.)
from the front and remove them (2.).
Reassemble by following these
instructions in reverse order.
 Insert the components carefully.

Removing the back panel

The back panel can be removed for
cleaning purposes.
Risk of injury caused by hot
surfaces.
The combination steam oven gets
hot during operation. You could burn
yourself on the heater elements, oven
compartment or accessories.
Allow the heater element, oven
compartment and the accessories to
cool before removing the back panel.
Risk of injury caused by the
rotating fan impeller.
You could injure yourself on the
impeller of the hot air fan.
Never put the combination steam
oven into operation without the back
panel in place.
Cleaning and care
 Disconnect the combination steam
oven from the mains. Switch off at
the wall and withdraw the plug from
the socket or switch off the fuse of
the electrical installation.
 Remove the side runners.
 Undo the four screws at the corners
of the back panel and take it out.
 Clean the back panel (see "Cleaning
and care – Cleaning the catalytic
enamelled back panel").
Reassemble by following these
instructions in reverse order.
 Refit the back panel carefully.
Make sure the openings are located as
illustrated in "Overview".
 Fit the side runners.
 Reconnect the combination steam
oven to the electricity supply.