Bosch AUTODOME 7100i Installation Manual page 25

Hide thumbs Also See for AUTODOME 7100i:
Table of Contents

Advertisement

AUTODOME 7100i│AUTODOME 7100i IR
Notice!
Notice
Use shielded twisted pair wire for all the connections such as a Belden cable with a foil
shield:
One shielded cable for:
- 24VAC or 36VDC and GND
i
2nd shielded cable for
- ALARM1 and DGND
- ALARM 2 and DGND
- RELAY-NO and RELAY-COM
- RELAY-NC and RELAY-COM
- AUDIO-IN+ and AUDIO-IN-
- AUDIO-OUT+ and AUDIO-OUT-
Notice!
i
Notice
The foil shield of the above two cables should be connected to the chassis ground
Notice!
i
Notice
The Ethernet cable should be CAT 5E, CAT 6 or better.
2.
Notice!
The following type of CAT 5E, CAT 6 or better Ethernet cable should be used:
i
F/UTP overall screened cable with unscreened twisted pairs (often referred to as FTP),
S/UTP overall braided shield with unscreened twisted pairs (often referred to as STP),
or with better shielding, and that meets the minimum bend radius of 30mm, and maximum
diameter of 0.24"(6mm).
3.
4.
5.
Bosch Security Systems
Connect the other end of the drain wire to a grounded metal box that supports
electrically grounded conduit.
X104
X105
X106
If you do not install fiber, skip to step 16.
To install fiber, complete the 8 steps that follow.
Remove the three (3) screws from the top cap to access the fiber connection.
Pull the top cap off the mount.
Installation Manual
Installing a pendant arm mount | en
25
2023-02 | V01 |

Advertisement

Table of Contents
loading

Table of Contents