Dicom Tags - Siemens NIC2-2 Installation And Startup Manual

Network id camera
Hide thumbs Also See for NIC2-2:
Table of Contents

Advertisement

NIC2-2 · Installation and Set-up Manual

3.5.4.1 DICOM Tags

Press SHIFT+F2 from the 'NICLan DICOM settings' window to open the DICOM tag editor.
NICLan DICOM Tags settings
01: N 0010,0010 1^2/1, 2
02: I 0010,0020
03: B 0010,0030
04: 1 0010,2110
05: Q 0040,0100
Move the highlight bar up and down using the arrow keys.
Press Shift+F1
Press Shift+F2
Press Shift+F3
Press F4
A maximum of 20 tags can be defined. Default values are:
01:
N
0010,0010 1^2/1, 2
02:
I
0010,0020
03:
B
0010,0030
04:
1
0010,2110
05:
Q
0040,0100
06:
L
0040,0001
07:
D
0040,0002
08:
T
0040,0003
09:
C
0000,0000
10:
S
FFFE,E000
N
Name. From this tag the name will be read. The value field is used to tell how to build
the name tag from the name parts during the search and how to build the name fields
N1 to N4 from the five parts of the DICOM NA type when processing the reply. The
string consists of one prefix and one to four parts where each part represents N1 to
N4. The prefix is separated from the other parts by a slash.
Example: 1^2/4 1|2, 3
The prefix is used to build the name item for the query from the name fields 1 and 2
in the search window of the NIC2-2. Each digit is replaced by the content of the corre-
sponding name field. All other characters are copied directly to the name item.The oth-
er fields are used to build the name fields 1 to 4 from the reply. Each part is separated
by a vertical bar '|'. Within each part, a digit will be replaced by the text in the corre-
sponding part of the DICOM NA field while the characters between the digits will be
used as separators between the name parts. If some name part is empty, only the sep-
arator following the previous non-empty name part shall be copied to the name field.
Neither shall the separators after the last non-empty name part be copied to the name
field. This shall ensure that in situations where some name parts are empty, separa-
tors shall never appear in the beginning or end of the string or that two separators shall
appear after each other without any name part them between.
Triacon AB Sweden
to edit a tag.
to inset a new tag. Note that the new tag will get the line number which is
highlighted when "Insert" is pressed. All tags below will be shifted down
one step.
to remove highlighted tag. All tags below will be shifted up one step.
to exit this window.
Exit
27
Publication no. 201101
October 2005

Advertisement

Table of Contents
loading