1.3. Safety instructions

DANGER
Escaping compressed gas
Risk of serious or even fatal injury from contact with escaping compressed gas or from unsecured plant
components.
DANGER
Mains voltage
Risk of serious or even fatal injury from electric shock when coming into contact with non-insulated,
powered components.
WARNING
Operation of unit outside limit range
If the specified limits are exceeded, there is a risk of device malfunction, potentially resulting in injury
and/or damage to property.
Specialist technical personnel
1
Specialist technical personnel have the professional training, knowledge of measurement, control, regulation and compressed air
technology and experience and knowledge of country-specific regulations, applicable standards and directives necessary to allow
them to carry out the work described and independently recognize potential hazards. Specialized usage conditions will require
additional knowledge, for instance regarding aggressive media.
METPOINT
SF53
®
Before carrying out any assembly, installation or maintenance work, depressurize the system. All
electrical work must be carried out by authorized specialist technical personnel
Use only pressure-resistant installation materials and suitable tools that are in proper working order.
Before pressurizing the system, check all unit parts and repair them, if necessary. Open valves slowly
to prevent pressure blows during operation.
Make sure that no persons can be injured or objects can be damaged by condensate or escaping
compressed gas.
Protect the device parts against vibration and impact.
For the electrical installation of the device, adhere to all applicable regulations (e.g. VDE 0100 / IEC
60364).
Before carrying out any maintenance work, de-energize the system.
All electrical work must be carried out by authorized specialist technical personnel
The permissible operating voltage is printed on the name plate and must be strictly adhered to.
All components of the electrical installation on site must be approved and/or bear the CE mark.
A reliably accessible circuit breaker (e.g. power plug or switch) that shuts off all conductors must be
installed close to the unit.
The device must only be operated for the intended purpose and within the permissible limits
specified on the type plate and in the technical data.
Use high-pressure protection above 10 bar to ensure safe installation and removal.
Do not operate the device in connection with flammable gases.
Strictly adhere to the prescribed operating times and maintenance intervals.
Observe the prescribed storage and transport conditions.
Prevent condensation on the sensor element. Ensure that the air fed through the device is free of
droplets.