Receiver Assembly Test - Philips 50 T Series Service Manual

Hide thumbs Also See for 50 T Series:
Table of Contents

Advertisement

Receiver Assembly Test

Chapter 8 - RF Bench Repair
7. Using an AC Coupler, connect the Preamplifier's output to the input
of the Spectrum Analyzer. The AC Coupler prevents the Spectrum
Analyser input from receiving 21 V DC.
The Spectrum Analyser should be set as follows:
START frequency
STOP frequency
Resolution Bandwidth
Video Bandwidth
Reference Level
The Spectrum Analyser measurement must be:
Frequency
Level
If this measurement is correct, complete Receiver Assembly Test.
8. Remove the BNC connector from the Preamplifier input and connect
this cable to the Spectrum Analyzer.
The Spectrum Analyser measurement must be:
Frequency
Level
9. If this measurement is correct, replace the Preamplifier Board. If this
measurement is not correct, replace the Coax cable. If this does not
solve the problem, replace the Receiver Processor Board (503).
1. Remove the flat cable and coax cable from the Receiver Assembly.
2. Pull out and turn over the Receiver Assembly and undo all 7 screws.
3. Lift up the top cover of the Receiver Assembly and connect the flat
cable again.
Receiver Assembly Test
400 MHz
500 MHz
100 kHz
100 kHz
-10 dBm
450 MHz
> - 32 dBm
450 MHz
> - 46 dBm