LE910Cx AT Commands Reference Guide
3.4.36.
AT+CEDRXRDP - eDRX Read Dynamic Parameters
This command returns a message related to Extended Discontinuous Reception (eDRX).
3GPP TS 27.007
3GPP TS 24.008
SIM Presence
Setting saved
Not required
AT+CEDRXRDP
Execution command returns the following message if eDRX is used for
the cell that the MS is currently registered to, in the format:
+CEDRXRDP: <AcT-type>[,<Requested_eDRX_value>[,<NWprovided_
eDRX_value>[,<Paging_time_window>]]]
If the cell that the MS is currently registered to is not using eDRX,
<AcTtype>=0 is returned.
Additional info:
Here is the list of the meanings of the parameter returned by the
+CEDRXRDP command.
80502ST10950A Rev. 14
Can be aborted
No
No
Name
<AcTtype>
Page 473 of 1904
Not Subject to NDA
MAX timeout
-
Type
Default
integer
0
type of access
technology.
Values:
0 : access technology is not
using eDRX
SELINT
2
Description
2022-03-04