5. MAINTENANCE

5.1.
PAPR CLEANING:
5.1.1.
Detach the battery pack, hose assembly and the blower. Inspect all parts for damage. Replace all damaged parts prior to storage
or next use.
5.2.
BLOWER
5.2.1.
Clean the outer surfaces of PAPR assembly and battery pack with a soft cloth dampened in a solution of water and mild, pH
neutral detergent.
DO NOT immerse the blower or battery pack in water.
DO NOT use solvents or abrasive cleaners.
DO NOT attempt to clean the interior of the blower with compressed air or vacuum.
Ensure the electrical contacts of the blower and battery pack are dry.
5.3.
HOSE ASSEMBLY
5.3.1.
Clean the connection joints on the hose assembly with water and a mild detergent solution.
NOTE: The hose assembly can be immersed in water for cleaning.
5.3.2.
Air dry or dry by connecting to the blower unit and blow dry the hose.
NOTE: The inside of the hose must be completely dried prior to use or storage.
5.4.
HEPA FILTER
5.4.1.
Remove the fi lter cover and inspect the fi lter.
5.4.2.
Replace if excessively dirty.
5.5.
CHANGING THE VISOR
5.5.1.
Release the stud from the bottom of the outside front of the face shield.
5.5.2.
Release the two tags on the outside bottom edge of the visor.
5.5.3.
Release the two sides and pull downwards to release the visor.
5.5.4.
Fitting a new visor is the reverse of the above.
5.6.
CLEANING AND DISINFECTION THE VISOR
DO NOT use abrasive materials.
5.6.1.
The lens is not scratch resistant. Be very careful when wiping, keep this to a minimum and use a soft, non-friction cloth.
5.6.2.
Clean with a soap and warm water or with ordinary household disinfectant.
5.7.
INSPECTION
5.7.1.
Face shields should be periodically inspected and cleaned. If it is damaged , pitted or anything that seriously aff ects the vision
through it, the lens must be replaced.
5.8.
STORAGE
5.8.1.
If the face shield with powered air purifying respirator is not to be used for an extended period, remove the fi lter and battery pack
and store in its original packaging in a clean, dry, cool place free of solvent based vapours.
5.8.2.
Face shield: Good storage conditions are very important for the service life of the face shield. It should be stored at temperatures
between 5ºC to 40ºC and 90% relative humidity. It should be kept away from solvents, solvent vapours or any corrosive materials,
because the protection eff ect of the face shield may be seriously reduced.
5.8.2.1.
When not in use it is recommended that the face shield is stored in its original packaging in a clean, dry, cool place.
NOTE: Safety visor screen (SSP80PAPR.13) only, has a product life of 2 years from date of purchase.

6. TROUBLESHOOTING

FAULT
Blower does not supply air to hood
Battery pack's charge lasts less than expected
Blower cannot be turned off
Battery red level light is fl ashing
Danger light is on, alarm sounds or blower vibrates
© Jack Sealey Limited
POSSIBLE SOLUTION
1. Press ON/OFF to start blower
2. Recharge battery
3. Verify battery is properly connected to blower
4. Remove blockage from blower outlet and breathing tube
1. Ensure battery pack is fully charged
2. Replace battery
3. Replace charger
4. Check the air fi lter (HEPA fi lter & Foam prefi lter), and replace it if necessary
Press ON/OFF button for one second
Charge or replace the battery
Check the blower air fl ow as section 4.11