4.9.5.
TO STOP
4.9.6.
Press the ON/OFF button (fi g 6 - 1) for approx one second, until the audible alarm and blower stops.
WARNING! If the danger indicator light (fi g 6 - 4) comes on, the audible alarm sounds and the blower (fi g 6 - 6) vibrates, this
indicates, that either the battery charge level is low, the air fl ow is reduced due to a dirty fi lter, the hose assembly is blocked or
there is another possible problem.
4.10.

BATTERY LEVEL INDICATOR

4.10.1.
The battery level indicator light (fi g 6 - 5) indicates the remaining charge in the battery.
4.11.
TEST AIR FLOW
4.11.1.
Disconnect hose assembly, SSP80PAPR.H05, (fi g 4 - 5) from face hood, SSP80PAPR.H04, (fi g 4 - 2).
4.11.2.
Insert air fl ow meter, SSP80PAPR.12, (fi g 7 - 1) into hose assembly connector, SSP80PAPR.H04, (fi g 7 - 3).
4.11.3.
Hold the fl ow meter vertically and start the blower (see section 4.9.1).
4.11.4.
The fl ow meter ball should fl oat above the MIN mark (fi g 7 - 2).
WARNING! If the fl ow meter indicates MIN or below turn the blower off (see section 4.9.5), then check the battery and fi lter
elements.
4.12.
HEAD SHIELD ADJUSTMENT
4.12.1.
Adjust the head shield circumference with the thumb wheel (fi g 8 - 1) on the back band of the face shield. The thumb wheel is
locked in position. Press the thumb wheel in to unlock, then twist clockwise to tighten and counterclockwise to loosen.
At the desired circumference release the thumb wheel back into the locked position, .
4.12.2.
Adjust the height by snapping the pin on the top band (fi g 8 - 2) into the required hole location to lock securely in place.
4.12.3.
To adjust the viewing angle, loosen the thumb wheels (fi g 8 - 3) on both sides of the head shied and change the angle locker to the
desired tilt position. There are 5 pre-set positions with the head shield supplied in the mid setting.
NOTE: The head shield should still be free enough to be raised up, but not to drift downwards.
4.12.4.
To adjust the distance between the user's face and the head shield's clear lens, loosen the thumb wheels (fi g 8 - 3) on both sides
of the head shield until the headband can move back and forth freely. Position the headband into one of the 3 slots (fi g 8 - 4), as
desired (the head shield is supplied in the mid setting). This should be completed one side at a time and both sides must be
located in the same location. Re-tighten the thumb wheels.
4.13.
CHECKING THE FACE SHIELD WITH POWERED AIR PURIFYING RESPIRATOR BEFORE USE
Before using the respirator, check the following items:
Air Filter Assembly: Ensure that the air fi lter is suitable for the application. Also be sure the fi lter is undamaged, and securely
connected to the blower assembly. See section 4.4.
Hose assembly: Ensure the tube is undamaged and properly connected to the blower assembly and hood. See sections 4.6 & 4.7.
Battery: Verify the battery is fully charged and securely connected to the blower assembly. See sections 4.1 & 4.2.
Air Flow: Test air fl ow according to Section 4.11.
Air Flow Alarm: Turn on blower assembly and check for audible, visual, and vibratory alarms. See section 4.8.
Face Hood: Inspect the face hood, ensure it is attached correctly and replace if damaged.
4.14.
PUTTING ON THE FACE SHIELD WITH POWERED AIR PURIFYING RESPIRATOR
4.14.1.
Place the blower assembly against the lower back with the hose assembly extending upwards (fi g 9).
4.14.2.
Fasten belt, SSP80PAPR.H08, around the waist and adjust to a comfortable fi t.
4.14.3.
Place face shield assembly over and onto to head. Ensure it is a comfortable snug fi t.
© Jack Sealey Limited
fi g.6
fi g.7
Original Language Version
BATTERY LEVEL INDICATOR
LEVEL INDICATOR LIGHT REMAINING POWER (%)
Green
90
Yellow
30 - 90
Red
10 - 30
Red - Flashing
0 - 10