Safety precautions ..................................Electronic equipment reception interference ........................Environmental requirements ..............................Technical specifications ................................ Permitted door weight and door width ..........................How the ASSA ABLOY SW60 works ..........................Control switch ....................................5.1.1 HOLD/AUTO/OFF switch ............................. Modes and functions on app ..............................
Page 4
Start-up ...................................... 12.1 Spring pre-tension ..................................12.2 App ........................................12.2.1 Install the app ................................12.2.2 Log in to the app with owner ........................... 12.2.3 Learn ....................................12.2.4 Test ....................................12.2.5 Settings .................................... 12.2.6 Add user ................................... 12.2.7 Remove user ................................... 12.2.8 Log in to the app with user ............................
2 Instructions for safe operation Instructions for safe operation Failure to observe the information in this manual may result in personal injury or damage to equipment. To reduce the risk of injury to persons - use this operator with single swinging only.
Important information Intended use The ASSA ABLOY SW60 is an automatic swing door operator developed to facilitate entrances to buildings and within buildings through swing doors. The ASSA ABLOY SW60 is an electromechan- ical operator approved for fire door applications. It is to be installed indoors where it is suitable for almost all types of internal swing doors.
Environmental requirements ASSA ABLOY Entrance Systems products are equipped with electronics and may also be equipped with batteries containing materials which are hazardous to the environment. Disconnect power before removing electronics and battery and make sure it is disposed of properly according to local regulations (how and where) as was done with the packaging material.
4 Technical specifications Technical specifications Ensure that the door operator with technical specification below is suitable for the installation. Manufacturer: ASSA ABLOY Entrance Systems US Inc. Address: 1900 Airport Road, Monroe, NC 28110, US Type: ASSA ABLOY SW60 Power supply:...
4 Technical specifications This product is to be installed internally. Permitted door weight and door width Permitted door weight and door width: Push arm: 150 Lbs. / 48" or 266 Lbs. / 36" Pull arm: 112 Lbs. / 48" or 200 Lbs. / 36" Note: Complies with UL 325.
How the ASSA ABLOY SW60 works The swing door operator ASSA ABLOY SW60 uses a motor which is connected to the output shaft. The push or pull arm system that is connected to the output shaft opens the door in a surface mounted application.
5 How the ASSA ABLOY SW60 works 5.2.6 Closing When the hold open time has elapsed, the operator will close the door automatically, using spring force and motor. The door will slow to low speed at latch check before it reaches the fully closed position.
8 Options Options Push plates For ADA compliance, center of push plate(s) must be 34"-48" above finished floor or height required by local AHJ. 8.1.1 Push plates 8.1.2 Remote transmitter push plates 8.1.3 Installation box for narrow plates 1020004-en-US-2.0 Issue 2020-10-27...
8 Options Labels Label kit Art. No.: 1020887 Dual Side “AUTOMATIC DOOR / CAUTION” Dual side "Operator designed for disabled people" Push side “PUSH TO ACTIVATE” Pull side “PULL TO ACTIVATE” Dual Side “Activate Switch to Operate” "AAADM safety" Product labels Issue 2020-10-27 1020004-en-US-2.0...
9 Pre-installation Pre-installation General tips/Safety concerns In all instances, where work is being done, the area is to be secured from pedestrian traffic, and the main power removed to prevent injury. Make sure that the power is off before installing. If there are sharp edges after drilling the cable outlets, chamfer the edges to avoid damage to the cables.
Expansion-shell bolt, min. M6x85, UPAT PSEA B10/25, min. 2" (50 mm) from the underside * ASSA ABLOY Entrance Systems minimum recommended requirements. Building Codes may give different specifications. ** Thinner wall profiles (1/8-3/16" / 3-5 mm) must be reinforced with rivet nuts.
10 Mechanical installation Mechanical installation The operator is mounted on either side of the door header depending on type of doors. The door is controlled with a push or pull arm system. Note: Consider all power wire entry locations and signaling wires before preparing back plate. 10.1 PUSH arm system 1020004-en-US-2.0...
11 Electrical connection Electrical connection Note: The installation shall be made according to local codes. During any work with the electrical connections the mains must be disconnected. Place the electric switch easily accessible from the operator. If a plug contact is used in the in- stallation the wall socket shall be placed easily accessible from the operator.
Page 36
11 Electrical connection Alt. 2 a Disconnect the mains power. b Fix the adaptor in the box. c Disconnected the power wire (1) from the terminal (3), and protect the power with insulated tapes. d Connect the adaptor wire (2) to the terminal (3). e Connect mains power to the adaptor.
Before the learning procedure starts, make sure that the door has been properly closed i.e., not by force. 12.2.1 Install the app Download the ASSA ABLOY Swing Door Manager app from the Google Play or iOS App Store. Issue 2020-10-27 1020004-en-US-2.0...
12 Start-up 12.2.3 Learn Note: If any of the parameters SPRING PRE-TENSION are changed after performing a learn, a new learn must be carried out. Back-check Latch-check The back-check will be automatically adjusted to 10° and 1 second before open position. The latch-check will be automatically adjusted to 10°...
12 Start-up 12.2.9 Configuration parameters Parameter name Default settings Value Hold open time 2.5s 2s - 6h Opening time 4.5s 4.5s - 9s Closing time 4.5s 4.5s - 9s Arm system Push Push / Pull Push and go Not active Not active / Active Power assist Off / Low / Medium / High...
14 Troubleshooting Troubleshooting Fault Possible reasons why Remedies/Explanations The door does not open Control switch is set to OFF Change the setting of the control switch The motor does not start Mains power is missing Check the mains power and fuse in the building LED light blinks Door is in error Remove power, wait 10 seconds.
Service/Maintenance Regular inspections shall be made according to national regulations and product documentation by an ASSA ABLOY Entrance Systems-trained and qualified technician. Regular scheduled mainte- nance should be in accordance with national requirements and product documentation. This is especially important when the installation concerns a fire-approved door or a door with an emer- gency opening function.
16 ANSI / BHMA A156.19 (LOW ENERGY APPLICATION) ANSI / BHMA A156.19 (LOW ENERGY APPLICATION) 16.1 REQUIREMENTS FOR LOW ENERGY POWER OPERATED DOORS The following texts are excerpts from American National Standard for low energy power operated swing doors. Please refer to the full standard if necessary. 16.1.1 Activation The operator shall be activated by a knowing act.
16 ANSI / BHMA A156.19 (LOW ENERGY APPLICATION) Table II Total Opening Time to 90 Degrees Backcheck at 60 degrees Backcheck at 70 degrees Backcheck at 80 degrees Table I plus 2 seconds Table I plus 1.5 seconds Table I plus 1second If the door opens more than 90 degrees, it shall continue at the same rate as backcheck speed.