Logitech 200 MKIII Series User Manual page 11

Tachometer

Advertisement

Variable Reluctance Magnetic Pickups
Set input type (IPUT) to standard sensitivity (STD) or high sensitivity (HS) depending
on target diameter and rotational speed. Connect the cable screen and one of the two
wires from the magnetic pickup to the common 0V terminals (shown as the black wire
below). Connect the other wire from the magnetic pickup to the input. Adjust sensitivity
to ensure that the correct value displayed at the minimum rotational speed.
Single Channel Operation
Gear Wheel or Flowmeter
Vs
0V
NC
NC
NC
NC
NC
0V
IPa
0V
IPb
Magnetic Pickup
Screen
Dual Channel (Ratio) Operation
Gear Wheel or Flowmeter
Vs
0V
NC
NC
NC
NC
NC
0V
IPa
0V
IPb
Magnetic Pickups
Screen
11