Front Panel 9 - Panasonic AK-HRP1010G Operating Instructions Manual

Remote operation panel
Hide thumbs Also See for AK-HRP1010G:
Table of Contents

Advertisement

Front panel 9

1
Camera number/tally display
2
[ALM] indicator
3
[OPT] indicator
4
[PANEL ACTIVE] button
5
[CALL] button
6
[PREVIEW] button
1
2
3
8
7
4
5
6
This display shows the camera number information and tally information.
This is the camera and CCU warning indicator lamp.
Consult your dealer if a failure occurs.
The indicator lights to indicate when the camera and CCU optical reception level is not
strong enough, when a data error has occurred in the CCU optical transmission/reception
section, or when a fan error or temperature error has occurred on the camera or CCU.
This is the camera cable warning indicator lamp.
Status displays
Lit (orange):
Warns that an optical transmission error has occurred.
Lit (red):
Indicates that the camera is not connected to the CCU.
Off:
The camera cable is connected normally.
Use this button to lock (disable) the panel operation.
When disabled, the LCD panel display will turn off. The [ND], [CC], [M.GAIN], and [SHUTTER]
setting buttons will also turn off.
Lock range
Status displays
On:
Enabled
Off:
Disabled
Press this button to call the camera operator.
The call switch on the camera and CCU is lit while this button is pressed.
Also, when the call switch is pressed on the camera or CCU, this switch lights and a buzzer
sound is output.
Status displays
On:
Indicates that the call switch on the camera or CCU is pressed.
Off:
Indicates that the call switch on the camera or CCU is not pressed.
Use this button to output a preview signal from the preview connector.
Pressing the [IRIS] lever also outputs the preview signal.
Status displays
On:
Preview output is On
Off:
Preview output is Off