A Power cord or other external cables plugged into the back of the
LCD can easily be removed by hand and/or screwdriver; 2 types of
connection of power cord are typical as shown in the pictures.
Capacitors > 25 mm are located in the power supply units and can
be removed by nipper. Possible it can be difficult to remove by
nipper due to shorter leads. In this case, the capacitors can be
removed by melting the solder which fixes the capacitors.