Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.
USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE
OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY INSTRUCTIONS
Maintain the pump in good condition (use an authorised service agent).
!
Replace or repair damaged parts. Use recommended parts only. Non-authorised parts may be
!
dangerous and will invalidate the warranty.
Keep the pump clean for the best and safest performance.
!
Wear appropriate protective clothing i.e gloves, safety glasses, overalls.
!
Install the pump in an appropriate working area. Keep area clean and tidy, free from unrelated
!
materials and ensure there is adequate lighting.
Maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes.
!
Keep children and unauthorised persons away from the working area.
!
WARNING! Turn off air supply and de-pressurise the output line before removing the pump,
F
dispensing gun or hose reel from any installation . Failure to comply with this instruction may
damage the units and will invalidate the warranty.
When not in use ensure the air supply is turned off.
!
DO NOT allow unauthorised persons to operate the pump.
%
WARNING! DO NOT tamper with, or open, the pump unit. To do so will invalidate the warranty.
F
DO NOT point air line at yourself, other persons or animals.
%
DO NOT use the pump to draw off any liquids other than oils.
%
WARNING! DO NOT allow uncontrolled discharge of fluids thus polluting the environment.
F
DO NOT force the pump to achieve a task it was not designed to perform.
%
DO NOT operate the pump when you are tired, under the influence of alcohol, drugs or intoxicating medication.
%
DO NOT use the pump for pumping flammable or corrosive liquids.
%
2. DESCRIPTION & APPLICATION
2.1.
A complete Oil Installation Pump Station may consist of an oil delivery pump AK4555D, a retractable hose reel AK4557D and a delivery
gun AK4558D with digital meter. These parts are available as separate items. In addition the hose reel and dispensing gun are available
together under part No. AK4556D. The system is intended to be installed in medium sized garage workshops to pump new engine oil
from a barrel or tank direct to a vehicle. Where the bulk oil storage is at a distance from the main work area the system can be plumbed
into a correctly specified pipe line. The dispensing gun with digital readout enables the operator to dispense the exact amount of oil
required. The meter also features an accumulative readout enabling a check to be made on the total amount of oil dispensed during any
day / week / month.
3. SPECIFICATION
Ratio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3:1
Maximum air pressure . . . . . . . . . . . . . . . . .8 bar (120psi)
Operating air pressure . . . . . . . . . . . . . . . . . .6 bar ( 90psi)
Max.output pressure . . . . . . . . . . . . . . . . . . .8 bar (120psi)
Transient peak pressure . . . . . . . . . . . . . . . . . . . . . .38 bar
4. CONTENTS
4.1
Check contents against items in fig.1 and fig.2. Remove items from carton, identify and check pieces for any damage. Contact supplier
immediately if you experience a problem.
AK4555D Pump :
(A) Pump
(B) 2” BSP adaptor for tank or
drum mounting.
(C) Inlet tube (flexible 1”) with
filter and non-return valve.
(D) Air supply hose (coiled)
with 1/4” bsp fittings.
(E) Outlet hose ( flexible 1/2”)
with shut off valve (F).
(G) Air filter/regulator with 1/4”
bsp fittings.
(H) Air lubricator with 1/4” bsp
fittings.
Pump kit
AK4557D
AK4556D Hose Reel + Gun :
(I) Retractable (10 mtr) hose
reel with 1/2” male inlet
fitting.
(J) Inlet hose (flexible 1/2”)
(K) Shut off valve.
(L) Drain cock / filter. ( female
fittings ).
(M) Dispensing gun with digital
meter ( male 1/2” inlet
fitting )
INSTRUCTIONS FOR
OIL INSTALLATION PUMP
STATION
AK4556D
Hose Reel + Digital meter
Digital meter available as
Max. free flow delivery . . . . . . . . . . . . . . . . . . .14ltr/m
Min. air pressure . . . . . . . . . . . . . . . . . . . . . . . . .3 bar
Air consumption at 6 bar . . . . . . . . . . . . . . . . . . . .9cfm
Air inlet port . . . . . . . . . . . . . . . . . . . . . . . . . .1/4” BSP
Output port . . . . . . . . . . . . . . . . . . . . . . . . . . .1/2” BSP
Suction port . . . . . . . . . . . . . . . . . . . . . . . . . . .1” BSP
Max. sound level at 1m . . . . . . . . . . . . . . . . . .75dB(A)
AK4557D Hose Reel only :
(I) Retractable (10 mtr) hose
reel with 1/2” male inlet
fitting.
(J) Inlet hose ( flexible 1/2”)
(K) Shut off valve.
(L) Drain cock. ( female
fittings ).
:
AIR OPERATED
CONSISTING OF
AK4558D
AK4555D
AK4558D Digital Gun only :
(M) Dispensing gun with digital
meter ( male 1/2” inlet
fitting )
AK4555D - AK4556D - AK4557D - AK4558D - 1 - 090802
:

Advertisement

loading

Summary of Contents for Sealey AK4555D

  • Page 1 2.1. A complete Oil Installation Pump Station may consist of an oil delivery pump AK4555D, a retractable hose reel AK4557D and a delivery gun AK4558D with digital meter. These parts are available as separate items. In addition the hose reel and dispensing gun are available together under part No.
  • Page 2 The bowl of the filter-regulator is fitted with an automatic drain valve the outlet of which may be piped away using suitably sized flexible tube. 5.14 Remove lubricator oil filler plug and fill with good quality air tool oil (Sealey ATO/500 500ml size or ATO/1000 1L size) checking the maximum level marked on the side of the unit. 5.15 Installing the self retracting hose reel and Gun.
  • Page 3 Retract the hose into the reel by giving a sharp pull on the hose close to the reel. Do not allow the retracting hose to drag the dispensing gun over the floor or return unaided. When filling operations are complete turn the air supply off. Keep the system clean, especially the dispensing gun and nozzle. AK4555D - AK4556D - AK4557D - AK4558D - 1 - 090802...
  • Page 4 This unit is designed to automatically lubricate the pump via the air supply. The unit must be kept topped up with good quality air tool oil (Sealey reference: ATO/500 - 500ml size or ATO/1000 - 1L size). To adjust the oil flow turn the oil regulator on the top of the unit.

This manual is also suitable for:

Ak4556d