Download Print this page
Sealey AK450DP Instructions

Sealey AK450DP Instructions

Air operated oil pump

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.
USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE
OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY INSTRUCTIONS
Maintain the pump in good condition (use an authorised service agent).
!
Replace or repair damaged parts. Use recommended parts only. Non-authorised parts may be dangerous and will invalidate the warranty.
!
Keep the pump clean for the best and safest performance.
!
Wear appropriate protective clothing.
!
Install the pump in an appropriate working area. Keep area clean and tidy, free from unrelated materials and ensure there is adequate lighting.
!
Maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes.
!
Keep children and unauthorised persons away from the working area.
!
Dispose of waste liquids in accordance with local authority regulations.
!
WARNING! Turn off air supply and de-pressurise the output line before removing the pump unit from any installation or mobile system.
F
Failure to comply with this instruction may damage the unit and will invalidate the warranty.
When not in use ensure the air supply is turned off.
!
DO NOT allow unauthorised persons to operate the pump.
%
WARNING! DO NOT tamper with, or open, the pump unit. To do so will invalidate the warranty.
F
DO NOT point air line at yourself, other persons or animals.
%
DO NOT use the pump to draw off any liquids other than oils.
%
WARNING! DO NOT allow uncontrolled discharge of fluids thus polluting the environment.
F
DO NOT force the pump to achieve a task it was not designed to perform.
%
DO NOT operate the pump when you are tired, under the influence of alcohol, drugs or intoxicating medication.
%
2. DESCRIPTION & APPLICATION
2.1.
Description
AK450DP is designed as a high volume transfer pump for the discharge of waste oil from Sealey models AK450DX, AK464DX and other
similar types of oil drainers. The pump is supplied with a wall mounting bracket and 2½ metres of flexible hose with a dry-fit quick coupling
to attach it to the drainer unit. 2 metres of flexible air supply hose with air management system are also included. The pump may be
plumbed into a run of pipe-work to a waste oil storage point. Recommended pipe diameter is 3/4” or larger.
The delivery performance will be affected by length and diameter of the delivery lines.
3. SPECIFICATION
Ratio . . . . . . . . . . . . . . . . . . . . . . . . . . .1:1
Maximum air pressure . . . . .8 bar (120psi)
Operating air pressure . . . . . .6 bar ( 90psi)
Minimum air pressure . . . . . .2 bar ( 30psi)
Max.output pressure . . . . . . .8 bar (120psi)
Max. free flow delivery
. . . . . . . . . .35L/m
Free flow delivery at 6 bar . . . . . . . .35L/m
Air consumption at 6 bar . . . . . . . . . .8cfm
4. ASSEMBLY & INSTALLATION
4.1.
Contents: Remove items from carton, identify and check
pieces for any damage. Contact supplier
immediately if you experience a problem.
1. Pump
2. Filter-regulator
3. Lubricator
4. Pressure gauge
5. Mounting bracket, filter-regulator
4.2.
Assembly
4.2.1. The air control unit items (fig.1. 2 & 3) have polycarbonate bowls and must not be installed where the bowls may be exposed to
materials incompatible with polycarbonate such as certain solvents and chemicals, or where fumes can weaken the bowls. If this is
unavoidable, an extension air line hose may be placed between the pump unit and the air control unit, but should not exceed 2 metres
(6½ft) in length. Note that a mounting bracket (fig.1.5) is supplied to provide support for remote positioned air control unit.
F
WARNING! Clean new air lines ensuring all metal shavings have been removed before connecting the pump and control unit. Any dirt in
the inlet lines could damage the unit and may invalidate the warranty.
Air inlet port . . . . . . . . . . . . . . . . .1/4” BSP
Output port . . . . . . . . . . . . . . . . .3/4” BSP
Suction port . . . . . . . . . . . . . . . . .3/4” BSP
Max. sound level at 1m . . . . . . . . .75dB(A)
6. Air inlet hose and fitting
7. Suction hose and fittings
8. Wall bracket, pump
9. Hex plug, regulator
10. Fitting, air system - 2 off
INSTRUCTIONS FOR:
AIR OPERATED OIL PUMP
AK450DP
Model:
fig. 1
AK450DP - 0444 - (2) - 190899

Advertisement

loading

Summary of Contents for Sealey AK450DP

  • Page 1 Description AK450DP is designed as a high volume transfer pump for the discharge of waste oil from Sealey models AK450DX, AK464DX and other similar types of oil drainers. The pump is supplied with a wall mounting bracket and 2½ metres of flexible hose with a dry-fit quick coupling to attach it to the drainer unit.
  • Page 2 This unit is designed to automatically lubricate the pump via the air supply. The unit must be kept topped up with good quality air tool oil (Sealey reference: ATO/500 - 500ml size or ATO/1000 - 1L size). To adjust the oil flow turn the oil regulator on the top of the unit.

This manual is also suitable for:

5024209287593