Kane KANE958 Manual

Kane KANE958 Manual

Flue gas analyser with direct o2 measurement and co sensor protection

Advertisement

Quick Links

KANE958
Flue Gas Analyser with direct O2
Measurement and CO sensor protection
KANE
LINK
Stock No: MAN00231 Rev: 1.00322
MARCH 2022
©
Kane International Ltd

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KANE958 and is the answer not in the manual?

Questions and answers

Summary of Contents for Kane KANE958

  • Page 1 KANE958 Flue Gas Analyser with direct O2 Measurement and CO sensor protection KANE LINK Stock No: MAN00231 Rev: 1.00322 MARCH 2022 © Kane International Ltd...
  • Page 2: Table Of Contents

    GENERAL OPERATING PRINCIPLE 11-15 QUICK START USER INTERFACE STATUS STATUS BAR STATUS BAR LAYOUT STATUS BAR MESSAGE AREA STATUS BAR ICONS STATUS BAR ICONS LEVEL STATUS BAR MENU OPTIONS STANDARD OPTIONS USING MENU MENU ITEMS MEASURING FLUE GASES 2 KANE958 MANUAL...
  • Page 3 VIEWING, SENDING & PRINTING PRESSURE MEASUREMENT GOOD PRACTICE LARGE BORE TUBING ISSUES PRINTING 24-25 KANE INFRARED PRINTER PRINTOUTS KANE LINK SPECIFICATIONS 27-28 EU DECLARATION COLD WEATHER PRECAUTIONS SERVICE - CALIBRATE - RECERIFY KANE ASSET MANAGER (KAM) 32-34 KANE958 MANUAL 3...
  • Page 4: Kane958 Overview

    “hands-free” operation and is supplied with a flue probe with integral temperature sensor. Your KANE958 has a low flow detector system to switch off the analyser pump if it detects water entering from an over filled water trap. Your KANE958 has a large 6 line display showing data and test results based on your actions.
  • Page 5: Analyser Features And Keypad

    ANALYSER FEATURES AND KEYPAD KANE958 MANUAL 5...
  • Page 6: Keypad Buttons

    Short press to scroll down NAVIGATE DOWN Short press to hold current data on screen - see status bar section on page 13 DATA HOLD Press to turn pump on or off PUMP ON/OFF Function Keys 6 KANE958 MANUAL Rotary dial...
  • Page 7: Analyser Layout

    - Differential Watertrap drain with red plug Pressure Connection P1 Red connector - plugs into Flue Flue Probe Temperature Plug - Gas Inlet Into T1 Narrow (+ve) pin must be on right side Flue probe hose KANE958 MANUAL 7...
  • Page 8: Back Of Analyser - Probe Etc

    Magnets x2 Thermocouple exhaust Stainless steel (P10) shaft Depth stop cone Water trap drain with red plug Thermocouple wire path 8 KANE958 MANUAL...
  • Page 9: Batteries

    After changing batteries reset your analyser time & date. CHARGING NiMH BATTERIES Your KANE958 uses a standard Micro USB connector - For best results turn off then connect your charger. Charging indicator will illuminate then turn off when charging is complete.
  • Page 10: General Safety

    Altitude to 2000m • Ambient temperature 0°C -40°C • Maximum relative humidity 80% for temperatures up to 31°C • decreasing linearly to 50%RH at 40°C Mains supply fluctuations not to exceed 10% of the nominal voltage • 10 KANE958 MANUAL...
  • Page 11: First Time Use

    GENERAL OPERATING PRINCIPLE Using your KANE958 is simple with the rotary dial and user interface. Most tests can be made with little user activity. Your analyser status bar offers options based on tasks you are performing and displays useful information and messages.
  • Page 12: Status

    No. of days until next calibration due Status bar STATUS BAR Status bar shows analyser status and offers options based on your settings. Navigate through status bar options via & buttons when status bar is on display. Status bar 12 KANE958 MANUAL...
  • Page 13: Status Bar Layout

    CALIBRATION DUE Display alternates WARNING MESSAGE between calibration due and current time AIR PURGE Display alternates air “SNOOZE” purge delay symbol & TIMER Current time LOW BATTERY Display alternates WARNING between BAT symbol & MESSAGE Current time KANE958 MANUAL 13...
  • Page 14: Status Bar Message Area

    Icons give quick and simple status information: STAUS BAR ICON LEVEL ICON LIST PUMP Pump status On or Off Analyser has logged/ LOGGED DATA stored data Data being sent to SENDING DATA App or Printer BATTERY Battery Status indication 14 KANE958 MANUAL...
  • Page 15: Status Bar Menu Options

    As you navigate up or down items will move up or down the screen returning to the beginning. Note: To exit menu turn your analyser rotary dial to any position - note any unsaved changes will be lost. KANE958 MANUAL 15...
  • Page 16: Menu Items

    Consists of a sub menu to: INFO - View firmware information UTIL UTIL B’LIGHT - Set backlight timeout (S) LEAK - Perform system integrity test Password protected for authorised service CODE CODE agents only - Default to 000000 16 KANE958 MANUAL...
  • Page 17: Measuring Flue Gases

    • Do not put analyser on a hot surface • Do not exceed analyser water trap levels • Do not let analyser particle filter become dirty and blocked • Check readings are stable and within expected range. KANE958 MANUAL 17...
  • Page 18: Co Protection Pump Operation

    Cursor flashes and line number appears in status bar. Use to select option to appear on line then press to enter option. O2/EFF SCREEN Oxygen reading Combustion efficiency T1 Flue Temperature T2 Inlet Temperature Nett Temperature Status bar 18 KANE958 MANUAL...
  • Page 19: Co/No Screen

    Loss reading Status bar STORED MEMEORY REPORTS Your KANE958 utilises a shared memory system which means stored logs are not limited by type. An icon displays when your analyser has stored data. To view current memory rotate dial to MENU then select LOGS to display.
  • Page 20: Viewing Stored Logs

    Returns to previous menu FINDING STORED REPORTS Once you select your report type the first stored log is displayed: LOG Number of that type Time and date of LOG Report readings specific to report type Navigation menu options 20 KANE958 MANUAL...
  • Page 21: Report Menu Options

    400 mbar. Rotate dial to Prs/Temp and use the black connectors & manometer hose to connect to P1 for single pressure or P1 & P2 for different pressure. Pressure connection Pressure P2 - Differential connection P1 KANE958 MANUAL 21...
  • Page 22: Temperature & Pressure Display

    - See PRINTING to print stored reports. PRESSURE MEASUREMENT GOOD PRACTICE WARNING Before using your KANE958 to measure an appliance gas/air ratio valve, read appliance manufacturer instructions thoroughly. If in doubt, contact appliance manufacturer. After adjusting a gas/air ratio valve CO, CO &...
  • Page 23: Large Bore Tubing Issues

    LARGE BORE TUBING ISSUES If using large bore tubing when performing pressure tests: Push orange tube over rim of spigot to ensure a gas tight seal. Failure to do so may not produce a gas tight seal. 23 KANE958 MANUAL...
  • Page 24: Printing

    PRINTING Press and release to send test results to your optional KANE IRP-3 printer or wirelessly to KANE APP. You can stop printing by pressing button again. KANE INFRARED PRINTER To use your printer, switch on and place the printer infrared receiver in line with the emitter on top of your analyser - allow a 15cm gap between analyser and printer.
  • Page 25: Printouts

    PRINTOUTS Combustion Auxiliary Pressure/Temp KANE958 MANUAL 25...
  • Page 26: Kane Link

    DATA TRANSFER You can wirelessly connect optional KANE LINK devices to your analyser. Rotate dial to KANE LINK on your analyser to manage how your analyser communicates with wireless devices. To wirelessly transfer data to a connected smart device running our KANE...
  • Page 27: Specifications

    Natural Gas, LPG, Light Oil, Digester Gas, Coke, Wood, European Heavy Oil, Coal Battery Life >8 hours (continuous with pump on) KANE958 is independently tested and certified to EN50379, Certification Parts 1-2 in accordance to 1st German Federal Emission Control Ordinance (BimschV) KANE958 MANUAL 27...
  • Page 28 SPECIFICATIONS CONTINUED Operating Conditions Temperatures 0 - 45°C Humidity 15 t 90% RH, (non-condensing) Power Supply Rechargeable batteries, USB Charging Physical Characteristics Weight Approx. 0.625g Dimensions 216mm x 105mm x 45mm 28 KANE958 MANUAL...
  • Page 29: Eu Declaration

    (EMC) 2014/35 Low Voltage Directive (LVD) The following harmonised standards and technical specifications have been applied: Certification The KANE958 is independently tested and certified to EN 50379, Parts 1 & 3 EN50270:2015 SAFETY EN61010-1:2010 ROSH (UK & EU)
  • Page 30: Cold Weather Precautions

    ‘ON’ sampling fresh air for a few hours. Connect your mains adapter or battery charger to avoid draining batteries If you still experience problems please contact Kane Customer Services. KANE958 MANUAL 31...
  • Page 31: Service - Calibrate - Recerify

    SERVICE - CALIBRATE - RECERTIFY All analysers & pressure meters should be recertified annually. Extend your KANE analyser & pressure meter’s ‘no quibble’ warranty up to 10 years by returning your analyser & pressure meter via your KAM dashboard annually.
  • Page 32: Kane Asset Manager (Kam)

    Report Stolen: Reporting your analyser stolen ensures our Stolen Analyser Register • is up-dated & helps prevent industry colleagues unknowingly buying stolen goods Remove your KANE Analyser once sold so it’s new owner can also benefit • There are different KAM options & we’d be delighted to discuss your Individual requirement More than 4 FGA’s? Contact: support@kane.co.uk...
  • Page 33 Your support - our way 33 KANE958 MANUAL...
  • Page 34 Book & pay to Service & Recertify via your KAM dashboard Select FREEPOST for tracked Carriage - UK mainland only Your analyser will be despatched on the same day we receive it… OR YOUR MONEY BACK* KANE958 MANUAL 34...
  • Page 35 THIS PRODUCT CONFIRMS WITH THE FOLLOWING PLEASE RECYCLE PACKAGING MADE IN THE UK 35 KANE958 MANUAL...
  • Page 36 Before use, please register on our website www.kane.co.uk Scan the QR code to go directly to Register your product online. Kane International Ltd Kane House, 11 Bessemer Road Welwyn Garden City Hertfordshire AL7 1GF, UK email: sales@kane.co.uk telephone: 0800 059 0800...

Table of Contents