Flue probe temperature (T1) Battery charger connection Inlet temperature (T2) Flue Gas Inlet Pressure connection Watertrap Drain with Red Screw Plug Pressure connection P2 (differential) Fit Spigot to Hose before connecting to Analyser...
Page 3
BEFORE USING ANALYSER CHECK THE FOLLOWING: Particle filter is not dirty inside Water trap and flue probe hose are empty of water Water trap and red screw plug are fitted correctly to the analyser Flue probe hose is connected properly to the flue gas inlet Flue probe temperature plug is connected into T1 temperature connection Please read the Safety Warnings in the User Manual FRESH AIR PURGE...
Page 4
/EFF display Oxygen left after combustion. Should be 20.9% in fresh air. 55.1 Flue temperature, (C) 17.2 Inlet temperature. Normally set by flue probe during fresh air purge. EfC% 98.3 Condensing boiler efficiency (EfC). Can be changed via “Menu” Press SEND to print a full combustion test. (Also sends to PC if Wireless module fitted). Hold SEND for 2+ seconds to log a full combustion report.
Page 5
When complete adjust the gas pressure if necessary then press to start the stabilisation period… STABIL’N Stabilisation display. 20.00 Real time pressure reading mbar TIME Stabilisation default time is 1 minute. Can be changed via “Menu”. When complete adjust the gas pressure if necessary then press to start the tightness test…...
Page 6
ROOM CO TESTING Select “Room CO” for CO investigations. Please refer to user manual. ROOM CO display ROOM Duration of this test is variable from 0 to 30 minutes as per BS7967 Real time CO reading, (ppm) TEST Test 00 = start. To stop the Room CO test press the PUMP button The complete Room CO test is automatically stored as a log number OTHER DISPLAY CODES -PO- = Pump Off...
USING THE MENU Select “Menu” on the rotary switch and navigate using the function buttons… = Scroll up = Scroll down = Enter MAIN MENU SUB MENU OPTIONS / COMMENTS NAT GAS, L OIL (28/35 sec), PROPANE, BUTANE, LPG, PELLETS SETUP SET FUEL (Wood)
Page 8
12. Printouts KANE455 V 1.00B KANE455 V 1.00B KANE455 V 1.00B YOUR COMPANY NAME & YOUR COMPANY NAME & YOUR COMPANY NAME & PHONE NUMBER HERE PHONE NUMBER HERE PHONE NUMBER HERE SERIAL NO. 000000000 SERIAL NO. 000000000 SERIAL NO. 000000000 DATE 01/07/14 PRESSURE...
PRODUCT REGISTRATION Please complete, detach and return to: Kane International Ltd Kane House, Swallowfield, Welwyn Garden City, Hertfordshire, AL7 1JG Your Details Name: Job Title: Company Name: Company Address 1: Address 2: Town/City: County: Postcode: Country: Phone Number: Fax Number:...
Page 10
Your feedback is important to us, please add any additional comments you would like to make with regard to your recent Kane purchase: Thank you for completing this survey. All the information we have collected is confidential. We do not sell or share data with any other company or organisation.
Page 12
Thank you for buying this analyser. Before use, please register on our website www.kane.co.uk Scan the QR code to go directly to Register your Product on-line or complete, detach and return the Product Registration form in this manual.
Need help?
Do you have a question about the 455 and is the answer not in the manual?
Questions and answers