• Cleaning and user maintenance shall not be made by children without supervision. General Safety • The appliance and its accessible parts become hot during use. Do not touch the heating elements. • Do not operate the appliance by means of an external timer or separate remote-control system. www.zanussi.com...
3 mm. Electrical connection • Use only correct isolation devices: line pro- tecting cut-outs, fuses (screw type fuses re- www.zanussi.com...
Page 4
• Do not put flammable products or items that • Clean the appliance with a moist soft cloth. are wet with flammable products in, near or Only use neutral detergents. Do not use on the appliance. abrasive products, abrasive cleaning pads, solvents or metal objects. www.zanussi.com...
Manufacturer decline any responsibility in case misuse of the flame If after some tries the burner does not light, check if the crown and its cap are in Always light the burner before you put correct positions. cookware. To light the burner: www.zanussi.com...
If the control knobs are under the Warning! Do not use a flame diffuser. bottoms of pots, the flame heats them up. Do not put the same pan on two burners. www.zanussi.com...
If necessary, remove stubborn stains Periodically speak your local Service Force using a paste cleaner. Centre to check the conditions of the gas sup- • Make sure you position the pan supports ply pipe and the pressure adjuster, if fitted. correctly after cleaning. www.zanussi.com...
The gas ring burns unevenly • Burner crown is blocked with • Make sure that the injector is food residues not blocked and the burner crown is clear of food particles. www.zanussi.com...
Also be compliance with standards and local careful when the hob is put together with an regulations in force. oven. www.zanussi.com...
Page 10
(or natural gas G20 13 mbar ) to liquid gas, – expired term is not due. fully tighten the by-pass screw in. If one or more defects are visible, do not repair the pipe, but replace it. 1) only for Russia www.zanussi.com...
Page 11
"N" on it. Con- nect the brown (or black) phase cable to the terminal which has a letter "L". Keep the phase cable connected at all times. a) Removable panel b) Space for connections www.zanussi.com...
Gas supply: G20 (2H) 20 mbar Appliance class: By-pass diameters Burner Ø By-pass in 1/100 Burner Ø By-pass in 1/100 Auxiliary Rapid Semi-rapid Gas burners for NATURAL GAS G20 20 mbar BURNER NORMAL POWER kW inj. 1/100 mm Auxiliary Semi-rapid www.zanussi.com...
>PE<,>PS<, etc. Discard the packaging mate- otherwise be caused by inappropriate waste rials as household waste at the waste disposal handling of this product. For more detailed facilities in your municipality. www.zanussi.com...
Page 22
• ....• (PNC) ....• (S.N.) ....MOD. MOD. MOD. TYPE PROD.NO. 230V-50Hz PROD.NO. PROD.NO. SER.NO. IP20 0049 SER.NO SER.NO 03 IT DATA DATA MADE IN ITALY MODEL MODEL « ». www.zanussi.com...