Cable Type "Profibus Ecofast Hybrid Cable" With 4X1.5+2X0.64 Mm - TR-Electronic PROFI BUS AE 70 Series Installation Manual

Absolute encoder
Table of Contents

Advertisement

Available languages

Available languages

PROFIBUS-DP RS485 Installation / Pre-commissioning

5.1.2 Cable type "PROFIBUS ECOFAST Hybrid Cable" with 4x1.5+2x0.64 mm

Devices which have the following marking on the name plate are equipped with this
cable:
Parameter
TR Order-No.:
Attenuation factor per length
- at 9.6 kHz / maximal
- at 38.4 kHz / maximal
- at 4 MHz / maximal
- at 16 MHz / maximal
Wave impedance
Loop resistance
Shielding resistance
Capacity
Conductor cross-section,
power wire conductor
Wire diameter
Cable diameter
Conductor insulation
Jacket
Bending radius, moved
Number of bending cycles
Tensile loading
Weighting
Temperature range
Protection class IP
Reaction to fire
Resistance against
- Mineral oil
- Grease
Resistance against
- UV radiation
Product characteristic
 TR-Electronic GmbH 2011, All Rights Reserved
Page 80 of 131
II 3G...;
II 2D...
Description
64-200-156X
0.0030 dB/m
0.0040 dB/m
0.025 dB/m
0.049 dB/m
150  ±10% at 3...20 MHz
138 /km
15 /km
30 pF/m at 1 kHz
1.5 mm
2.56 mm
11 mm ±0.3 mm
PE
PUR
≥ 7.5x outer diameter
5000000 at 2.5 m/s
≤ 300 N
150 kg/km
-40...+60 °C
IP 65
flame retardant,
IEC 60332-1
conditionally resistant
conditionally resistant
free of halogens and
silicone
TR - ECE - BA - DGB - 0089 - 04
2
2
2
Illustration
Printed in the Federal Republic of Germany
02/03/2016

Advertisement

Chapters

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PROFI BUS AE 70 Series and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Profi bus aew-70Profi bus aev-70

Table of Contents