7 Changing/Setting Models
Change or configure the model type for Auto Mode. On the ANUJ5010 Aicure, each of the 4 LED
heads can be configured independently with 10 different irradiation patterns. Additionally, the
combinations of irradiation-pattern settings of LEDs 1 to 4 can be saved as 10 different model types.
Do display the Model Select screen, touch MENU → TYPE CHG.
■ Changing Models
20
1
Check the current settings.
The current settings are shown for the inverted number.
Touch the down arrow (↓) to display numbers 7 through 10.
2
Touch the number to modify.
A confirmation screen appears. External signals have
precedence for model selection. If the external signal is 0
("all off"), the system switches to the model configured on
the main unit.
3
Touch YES.