■ The Setup Sequence
The sequence required to configure the ANUJ5010 Aicure for use is described below.
Name and Function of Each Part
Turn on Power
1
Plug the power cord into the main unit.
2
Plug the connection cable into the main unit.
3
Plug the connection cable into the LED head.
4
Attach the LED to the jig.
5
Insert the power key into the main unit, and turn it 90
degrees.
Setting up for Manual Operation (Parameter Setup)
6
Touch MENU to return to the Menu screen, and switch to
MANUAL.
7
Configure the light modulation ratio (initial setting: 100%).
8
Select an LED (inverted display).
9
On the main unit, press the START button (irradiation
begins).
The light modulation ratio can be changed during irradiation.
10
Press the START button again (irradiation stops).
Model Setup
11
On the Menu screen, touch TYPE CHG to change to the
Model Switch screen.
12
Select a model (initial setting: TYPE NO. 1)
External signals have precedence for model configuration. If the
external signal is 0, the system switches to the model configured
on the main unit.
13
Touch TYPE SET to change to the Model Setup screen.
14
Configure the model (1 to 10) for each LED (initial setting:
LED 1 = 1, LEDs 2 to 4 = 0 ).
15
Touch PATTERN to change to the Pattern Setup screen.
16
Select a pattern number (P1 to P10).
17
Configure the time and intensity for steps 1 to 10 (initial
setting: step 1 = 10.0 seconds 100% intensity; steps 2 to 10
= 0 seconds, 0% intensity).
To terminate the steps midway, set the time to 0 seconds.
Auto Mode Setup
18
On the Menu screen, select Pulse or STAT and Multi. Or
ALL (initial setting: Pulse, ALL).
9