4.8

Ambient Conditions

For indoor use only.
The PRS-200 was calibrated at an ambient temperature of 20 °C (+/- 3
°C).
The permissible operating temperature is between 5 °C and 40 °C.
The permissible relative humidity is between 20% and 80%.
Always keep the PRS-200 free of dirt, dust, and corrosive gases.
5.

INSTALLATION

5.1

General Notes on Installation

Requirements
The axis must be screwed onto a surface with an evenness better than 5
µm.
It is necessary to make sure that no dust, dirt or other foreign bodies are
between the surface and the axis, otherwise the properties of the axis can
be impaired by mechanical tension.
To guarantee the prescribed specifications (see Internet www.pimicos.com),
the evenness of the mounting surface must be better than 5 µm.
5.2

Mounting the Rotation Stage

Requirements
You have read and understood the general notes on installation (see
chapter 5.1).
Mounting material
screws, pins and auxiliary material or tools supplied (see chapter 4.5
"Scope of Delivery").
DIN 912 screws and ISO2338 dowel pins, h8 tolerance field
Tightening torques of the mounting screws to be used should not have
values higher than the following:
M3 DIN 912 1.5 Nm
M4 DIN 912 2.0 Nm
M5 DIN 912 2.5 Nm
M6 DIN 912 3.0 Nm
Mounting the PRS-200
1. Mount the rotation stage with the screws supplied.
2. Make sure that the screw heads do not protrude from the countersunk
holes.
www.pimicos.com // info@pimicos.com // phone:+49(0)7634-50 57 0 // fax:+49(0)7634-50 57 393
PRS-200 Precision Rotation Stage 13