WYLER Clinotronic S Manual

WYLER Clinotronic S Manual

Electronic inclinometer
Hide thumbs Also See for Clinotronic S:

Advertisement

Quick Links

Manual Clinotronic S
Manual
Electronic Inclinometer
S
Clinotronic
WYLER AG
Im Hölderli 13
8405 Winterthur
Switzerland
+41 233 66 66
www.wylerag.com
wyler@wylerag.com
Technical changes reserved
1 / 45
947-MA-0004-E R3.0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Clinotronic S and is the answer not in the manual?

Questions and answers

Summary of Contents for WYLER Clinotronic S

  • Page 1 Manual Clinotronic S Manual Electronic Inclinometer Clinotronic WYLER AG Im Hölderli 13 8405 Winterthur Switzerland +41 233 66 66 www.wylerag.com wyler@wylerag.com Technical changes reserved 1 / 45 947-MA-0004-E R3.0...
  • Page 2: Table Of Contents

    Manual Clinotronic S Contents 1. Manual Clinotronic S ..........................3 Introduction ................................. 3 Note, Attention !, Warning! ............................3 Manufacturer name and address ..........................3 Product brand and type designation ........................... 4 Applicable documents ..............................4 2. Product description, technical data ....................... 5 Measuring device, accessories ...........................
  • Page 3: Manual Clinotronic S

    1. Manual Clinotronic S Introduction Before you start Read this manual carefully before using the Clinotronic S for the first time. Please also note the safety instructions. Note: Incorrect manipulations or unintentional deletion of calibration data will be prevented by these instructions.
  • Page 4: Product Brand And Type Designation

    2 M3 threads on all sides *Subject to change Applicable documents https://www.wylerag.com/fileadmin/pdf/cerificates_DoC/DoC_Clinotronic S_R2.pdf The CE Declaration of Conformity can be found on our homepage at: www.wylerag.com at the product page Clinotronic S "Download". Technical changes reserved 4 / 45 947-MA-0004-E R3.0...
  • Page 5: Product Description, Technical Data

    Measuring device, accessories The measuring device The housing of the Clinotronic S is made of black anodized aluminum. The 4 measuring bases are located in each of the quadrants (frame). The front and back are equipped with a plastic film.
  • Page 6 Manual Clinotronic S Optional accessories www.wylerag.com Soft ware Interface software Geometry measuring software Monitoring soft ware Software tools Calibration wylerMASTER Remote display Android smartphone with installed App Energie Extra Li-ion-Batteries External charger for max two Li-ion batteries Technical changes reserved 6 / 45 947-MA-0004-E R3.0...
  • Page 7: Safety Instructions

    • The device complies with the applicable directives and standards Consult: - The current CE Declaration of Conformity Clinotronic S - This instruction manual and the quick reference - The type label on the back of the device Intended use •...
  • Page 8: Additional Information For Fcc (Usa) And Ic (Canada)

    Manual Clinotronic S Additional information for FCC (USA) and IC (Canada) FCC part 15 und ICES-0003 Device Class A This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation”.
  • Page 9: Safety Instructions Lithium Ion Batteries

    Manual Clinotronic S Safety Instructions Lithium Ion Batteries The lithium ion batteries 3.6Vare rechargeable Type of battery: 18650 Only the original type 18650 lithium ion batteries may be used Lithium-ion batteries are only allowed to be charged with the supplied chargers.
  • Page 10: Deadlines For Calibration

    For monthly use: every 2-3 years • WYLER AG operates a calibration center for the parameters length, planarity and angles according to EN / ISO / IEC 17025. • The accreditation is carried out by METAS. WYLER accreditation number: SCS 044...
  • Page 11: Prepare Product For Use

    Manual Clinotronic S 4. Prepare product for use Content of case (including accessories) Case Clinotronic S Lithium-ion-Batteries 3.6V, Type 18650 USB power adapter Cable USB-A/USB-C wylerTRIGGER Infrarot(IR) trigger wylerCONNECT MINI → Quickreference → Manual download at www.wylerag.com Note: Scope of delivery of the accessories is defined in the actual catalog!
  • Page 12: Controls

    Manual Clinotronic S Controls • Screen • On/Off • Menu Enter • Arrow button down Short cut (hold 2 seconds) "Relative Zero" • Back/cancel • Lithium-ion battery lid • USB-C connection • wylerTRIGGER Infrared (IR) trigger Technical changes reserved 12 / 45...
  • Page 13: Charging With Power Adapter Or Operate On The Laptop

    Usage via USB cable to the PC or laptop Connect the Clinotronic S with the cable to the PC or laptop The Clinotronic S is powered via the USB socket of the PC. The device remains in measuring mode Note: If the device is connected to the PC via the USB cable, it is operated electrically.
  • Page 14: Operation

    Visit: www.wylerag.com Connected via cable (USB-C / USB-A) with a Windows computer Note: With the cable you can update the firmware of the Clinotronic S via Windows computer. The corresponding firmware loader can be found at www.wylerag.com Technical changes reserved 14 / 45 947-MA-0004-E R3.0...
  • Page 15: Measurment Bases

    Manual Clinotronic S 5.2 Measurment bases The device is equipped with four (4) measuring bases with flat measuring surfaces Horizontal application Measurement base above Measurement base below Vertical application Measurement base left side Measurement base right side Technical changes reserved 15 / 45 947-MA-0004-E R3.0...
  • Page 16: Screen Overview And Keyboard

    Manual Clinotronic S 5.3 Screen overview and keyboard • Screen • Serial number; 2a IR number + 1 x flash when triggered • Display of value (depending on the selected unit) • Radio activated, not activated: • Charge indicator , empty , charging •...
  • Page 17: Switching On/Off, Measuring Range

    Manual Clinotronic S 5.4 Switching On/Off, Measuring Range Switch On • Press the button The screen starts immediately. Note:The device starts with the last used settings Switch Off • To switch off press the button until the following message appears: Release the button.
  • Page 18: Menu "Settings", Entry And Exit

    Manual Clinotronic S 5.5 Menu "Settings", entry and exit • Press the button to enter into menu "Settings" In "Settings" contents: Device ......Unit......Measurement....Device Information..• Use the arrow up and arrow down to move the cursor up und down.
  • Page 19: Settings In "Device

    Manual Clinotronic S 5.6 Settings in "Device" Enter with into the menu "Settings" • Select with the item "Device" • after that press: • "Device" contents: Brightness ......Bluetooth......Zapper teach-in....Technical changes reserved 19 / 45 947-MA-0004-E R3.0...
  • Page 20: Device: "Brightness

    Manual Clinotronic S 5.6.1 Device: "Brightness" • In the menu"Devices" select with the item "Brightness" • Select with the desired brightness: Medium High • Confirm with your choice • cancel with Note In both cases you will jump back to the "Device" menu Attention !: Depending on brightness level the unit consumes more power.
  • Page 21: Device:"Bluetooth

    Manual Clinotronic S 5.6.2 Device:"Bluetooth" • In the menu "Device" select with the item "Bluetooth" • Select the desired setting: • Confirm with your choice • cancel with Note In both cases you jump back to the "Device" menu Technical changes reserved 21 / 45 947-MA-0004-E R3.0...
  • Page 22: Zapper Teach-In

    Manual Clinotronic S 5.6.3 Zapper teach-in • In the menu "Device" select with the item "Zapper teach-in" • Press the zapper (Infrared trigger) until "OK" appears. • The zapper (Infrared trigger) is identified. • When the zapper is pressed, the IR number appears in the top line for 1 second Note: You can "Teach-in"...
  • Page 23: Settings In "Units

    Manual Clinotronic S 5.7 Settings in "Units" Enter with into menu "Settings" • Select with the item "Units" , after that: "Units" contents: Unit digits Explanation • DEG°\′\″ ## ° ## ' ## " Degree - Minute - Second •...
  • Page 24: Units

    Manual Clinotronic S 5.7.1 "Units" • In the menu"Units" select with the desired unit • Confirm with e.g.: mm/m The digits and the unit adapts accordingly your choice Note Always check the unit at the beginning of a measurement! Technical changes reserved 24 / 45 947-MA-0004-E R3.0...
  • Page 25: Self-Selected Base Mm/Xxxx Mm

    Manual Clinotronic S 5.7.2 Self-selected base mm/xxxx mm Note The unit mm/xxxxmm allows a freely selectable base length • In the menu "Units" select with the item mm/1435mm Note 1435 is the last selected value, hence it may be different.
  • Page 26: Type Of Measurement

    Manual Clinotronic S 5.8 Type of Measurement In the menu"Devices" select with the item "Measurements" • after that: • The menu "Measurement" contents: Absolute....uses last measured zero deviation Absolute Zero ..triggers reversal measurement (zero deviation) Relative Zero..current position becomes reference level (relative zero)
  • Page 27: Absolute Measurement

    Manual Clinotronic S 5.8.1 Absolute measurement Enter with into Menu "Measurement" • In the menu"Measurement" select with the item "Absolut" • after that: • The device returns into the measurement mode Note: How to use: Device is in Relative Zero mode.
  • Page 28: Reversal Measurement "Absolute Zero

    Manual Clinotronic S 5.8.2 Reversal measurement "Absolute Zero" Enter with into Menu "Measurement" • In the menu"Measurement" select with the item "Absolut Zero" after that: The menu now guides you through the reversal measurement • Place the device on a flat and stable surface. → Position H Note To get a reliable reversal measurement the plateau should be aligned within +/- 0.06mm...
  • Page 29 Manual Clinotronic S Please wait, the device records a stable value H. Attention !: Please do not touch the device until the measured value is recorded! Now turn the device at the same position by 180°. → Position H •...
  • Page 30: Temporary Reference Level "Relative Zero

    Manual Clinotronic S 5.8.3 Temporary reference level "Relative Zero" Enter with into Menu "Measurement" • In the menu"Measurement" select with the item "Relative Zero" after that: The menu now guides you through the reversal measurement "Relative Zero" • Note Shortcut! You can choose "Relative Zero" directly from the measurement mode by pressing 2 seconds (and then release) the button •...
  • Page 31 Manual Clinotronic S Please wait, the device records a stable value H. Attention !: Please do not touch the device until the measured value is recorded! The instrument will return to measuring mode immediately after reading the measured value H.
  • Page 32: Device Info

    Manual Clinotronic S 5.9 Device Info Enter with into the Menu "Settings" • Select with the item "Device Information" • after that: • "Device Info" contents: Device Information Firmware etc. Advanced Settings Note: with you return back into the Menu "Settings".
  • Page 33: Device Info

    Manual Clinotronic S 5.9.1 Device Info Enter with into the Menu "Device Information" List of internal data. The firmware version changes when a firmware update has been made. • Note: with you return back into the measurement mode. Technical changes reserved 33 / 45 947-MA-0004-E R3.0...
  • Page 34: Advanced Settings

    Manual Clinotronic S 5.9.2 Advanced Settings Enter with into Menu "Device Information" • Select with the item Advanced Settings, after that press: Select with the item "Yes" Attention !: This procedure prevents accidental manipulation. Attention !: In this menu, calibration data are affected! If you have any questions, please contact our local representative.
  • Page 35: Use Local Gravity

    Manual Clinotronic S 5.9.2.1 Use Local gravity In the menu "Device info" select with the item " Advanced Settings". • Enter with "Use local gravity" after that: ▪ Navigate with to the right to the left ▪ The value of the numbers change with...
  • Page 36 Manual Clinotronic S The device returns to measuring mode. Note The measurement mode shows the globe symbol as a sign of using the local gravity Technical changes reserved 36 / 45 947-MA-0004-E R3.0...
  • Page 37: Disable Local Gravity

    Manual Clinotronic S 5.9.2.2 Disable local gravity In the menu "Device info" select with the item " Advanced Settings". • Select with "Disable local gravity" after that: The globe icon disappears, so the default value of 9.8065 is restored. Technical changes reserved 37 / 45 947-MA-0004-E R3.0...
  • Page 38: Wylermaster Calibration

    Manual Clinotronic S 5.9.2.3 wylerMASTER calibration Attention!: A calibration with the wylerMASTER requires the input of your local gravitation constant. It becomes the new reference! This makes it possible to continue to use the item "Use local gravity"! With factory reset you can return to factory settings.
  • Page 39 Manual Clinotronic S The calibration begins: Note The menu will guide you through the process. • Position the device on the wylerMASTER in position 1/21: - 50 ° With the trigger or pressing start the measurement. Note: You can cancel the calibration at any time with The last calibration is retained.
  • Page 40 Manual Clinotronic S Note You can measure a failed calibration point again. Press the last measurement is canceled. E.g. from 0° back to -5° • Carry out the calibration according to the above steps until the 21st (last) measurement. •...
  • Page 41 Manual Clinotronic S Note You can cancel this process at any time with and return to the measurement screen Please wait, the device records a stable value H. Attention !: Please do not touch the device until the measured value is recorded! •...
  • Page 42 Manual Clinotronic S Note If the device is in the wrong position, an error message "Wrong Position" appears. 1. Acknowledge this message with 2. Position the device as required by the user interface.. Example Note The measuring range after a wylerMASTER calibration is 45 °...
  • Page 43: Factory Reset

    "Factory Reset" Attention !: This procedure prevents accidental manipulation Attention !: The Clinotronic S contents now original data in memory. For a precise absolute measurement please carry out a reversal measurement process according to chapter 5.8.2. Technical changes reserved 43 / 45 947-MA-0004-E R3.0...
  • Page 44: Maintenance

    Tel. +41 52 23 66 66 Fax +41 52 233 53 20 www.wylerag.com wyler@wylerag.com For questions, if you are outside Switzerland in a country with a WYLER representative: Country representatives: www.wylerag.com/en/contact/representatives/ otherwise contact us directly Technical changes reserved 44 / 45...
  • Page 45: Disposal

    Manual Clinotronic S 7. Disposal Decommissioning, disposal • When decommissioning the Clinotronic S, note the local regulations for the disposal of electronic waste. • The Li-ion batteries must be disposed properly. 8. Document version and release notes Date Text: Author: checked 02.05.