Controls / brief overview 3.1. Overview of keyboard and display 3.1.1. Overview of keyboard and display for wylerLEVEL 3.1.2. Overview of keyboard and display for wylerCLINO 3.1.3. How to switch the device on and off 3.1.4. Keys / functions / brief description of the individual keys 3.2.
E F O R E Y O U B E G I N Carefully read through this operator’s manual before you begin working with the wylerLEVEL for the first time, as it contains an overview of the many functions and options that the device offers. Doing so will familiarize you with the various controls available.
T A N D A R D E Q U I P M E N T Case for storage, transport, and shipping for repair wylerLEVEL / wylerCLINO, 2 Type C 1.5 V batteries Quick Reference guide (For Operator’s Manual see: www.wylerag.com) (For accessories see: www.wylerag.com)
Use as a standalone device Connect wylerLEVEL / wylerCLINO to a PC via wireless and wylerCONNECT Connect wylerLEVEL / wylerCLINO to a PC using a cable connection via wylerCONNECT Page 6 of 52 Pages V 1.0...
Page 7
/ wylerCLINO connected with the wylerAPP wylerLEVEL / wylerCLINO connected to BlueMETER SIGMA via cable Connect wylerLEVEL / wylerCLINO with BlueMETER SIGMA wirelessly Possible example applications are described in our Instrumentarium, which is available on our homepage: https://www.wylerag.com/en/applications/projects-with-wyler-systems/ Page 7 of 52 Pages...
A T T E R Y M A I N T E N A N C E When not in use for longer periods, the wylerLEVEL should be stored in the carrying case provided. Read the instructions and tips in the Operator’s Manual before installing the batteries. Ensure that the batteries are installed correctly.
Page 9
manufacturer’s specification and size when replacing the batteries. Replace all batteries at the same time. If storing the device for longer periods of time, it is recommended that you remove the batteries from the device and store them at room temperature in a dry location. Do not dispose of old batteries in fire. Batteries must not be recharged unless labelled “rechargeable.”...
O W T O S W I T C H T H E D E V I C E O N A N D O F F The wylerLEVEL features an automatic shut off. In normal mode, the device shuts off automatically 60 minutes after the last key operation.
Page 12
ON/MODE Key Function - 4 - When setting a numerical value, you can use the key to set the default value. ENTER Key Function - 1 - Use the key to save an entered value, or to confirm a selected function.
Page 13
HOLD Key Function - 1 - is used to “freeze” a measuring value. The value is displayed until the wylerLEVEL is returned to Measuring mode, which is done by pressing SEND key. Function - 2 - In the functions REL.ZERO and ABS.ZERO, the key is used to input the current measuring value again during manual entry.
3 . 2 I S P L A Y The wylerLEVEL features various graphic displays that can be selected and scaled according to the requirements of the measuring task. The background color and brightness can also be adjusted. 3 . 2 . 1 S C A L I N G O F T H E D I S P L A Y A variety of scaling options are available in order to facilitate optimal use of the graphic display.
Page 15
The following display types are available in the wylerLEVEL: Numeric display Numeric display plus bar graph Numeric display plus 3 bars, each with a 10 times higher resolution Numeric display plus level (spirit level) Numeric display plus simple level (spirit level)
Numeric display plus needle 3 . 2 . 3 B A C K G R O U N D C O L O R The background color can be set in the device Settings. Depending on the brightness of the selected color, the color of the text and symbols will be either black or white.
Page 17
The wylerLEVEL includes the following background colors: Background: blue Background: black Background: beige Background: orange Page 17 of 52 Pages V 1.0...
3 . 2 . 4 B R I G H T N E S S The brightness of the display can be adjusted in the device Settings in order to adapt the display to the surrounding conditions and to optimize battery life. Thus, two different values can be set - for operation with external power supply, and battery operation.
3 . 3 R I E F D E S C R I P T I O N O F V A R I O U S P A R T S O F T H E D I S P L A Y Main The current measuring value is shown in the main display.
Page 20
Serial number Displays the serial number of the device. Displays the current battery voltage (example: 2.6 V) The lowest possible voltage is 1.7 volts. If the voltage continues to Battery voltage drop, a blinking battery symbol will appear. The batteries must then be replaced immediately.
S E R S M A N U A L F O R W Y L E R The wylerLEVEL offers a wide range of functions and settings options. The list of functions appears when key is pressed. Using the...
Page 22
OFFSET. Note: The value of the ZERO OFFSET determined by a reversal measurement corresponds to the deviation of the zero point of the wylerLEVEL compared to the absolute zero point. The readout on the display corresponds to: Displayed VALUE = Value of the device minus the zero offset.
Place the wylerLEVEL on a stable base. Now press the key. While the wylerLEVEL is waiting for a valid measuring value, the display will show a graphic depicting the measuring values read as a set of points.
Page 24
Complete the measurement with the key, or by using the zapper. After 15 seconds the measuring value will be automatically read. By pressing the key again, a new valid measuring value will be read. Page 24 of 52 Pages V 1.0...
B S O L U T E M E A S U R E M E N T As a factory setting, the wylerLEVEL is programmed for absolute measurement (default setting). If this is not the case, select the function [Absolute]. After this function has been confirmed with the key, the device is ready for measurement in ABSOLUTE mode.
OFFSET, e.g. determined by a reversal measurement. The REL ZERO OFFSET is stored in the wylerLEVEL, and can be recalled repeatedly. When conducting the next relative measurement, the REL ZERO OFFSET that is displayed is the one that was entered or determined the last time the device was used.
Page 27
At this stage, you can use the key to enable manual entry in order to enter a reference value that you have defined. Place the wylerLEVEL in position and press the key to input the value. Alternatively, the zapper can be used to begin the measurement.
"0". By pressing the key, the displayed value is adopted and the procedure is completed. With the key, the procedure is abandoned without any changes. The wylerLEVEL subsequently returns to Measuring mode.
1. On the wylerLEVEL, use the key to select the LEAVE menu. Confirm with the key. 2. The wylerLEVEL is removed from the group, and is no longer accessible via wireless data transmission. Page 29 of 52 Pages V 1.0...
The wylerLEVEL is equipped with an integrated calibration setup for a quick calibration procedure that allows the device to be calibrated without requiring a complex procedure. On the back of the wylerLEVEL there are precisely milled holes designed to hold dowel pins as calibration aids. These pins are part of the delivery and can be inserted into the holes.
Page 31
After a successful calibration the device restarts. Finally, the correction of the zero point (absolute ZERO) must be determined via a reversal measurement. The wylerLEVEL has now been recalibrated and can be used for further measurements. Page 31 of 52 Pages V 1.0...
• Using the IR zapper, hold the trigger depressed until the two red IR LEDs illuminate Repeat this procedure on all the measuring and display devices that will be using the same IR triggering. This procedure is Wyler TRIGGER carried out on our devices prior to them leaving the factory. Page 32 of 52 Pages...
P T I O N S The options serve as input for the basic settings of the measuring device. Access to the options can be protected by means of a PIN code in order to prevent unauthorized adjustments. The following options are available: Set PIN Code •...
The brightness of the display, including the brightness in power management mode, and the color scheme can all be adjusted. The wylerLEVEL runs in power management mode if the device is not connected to an external power supply, and the device is operating on battery power. Brightness is expressed as a percentage of maximum brightness.
Using the key, select the menu item [Options] and confirm the selection with . Now select [Display Settings] and confirm with Display Settings -> Brightness Brightness Battery Using the keys, select the Display Settings that Color you want to change and confirm your choice with the key.
5 . 4 R O G R A M M A B L E K E Y S The function of the keys and the key can be switched on or off. Using the key, select the menu item [Options] and confirm your choice with .
5 . 5 O N / O F F U N C T I O N S The built-in menu functions can be switched on or off. Thus, the menu displayed can be adjusted to meet the needs of the user. Using the key, select the menu item [Options] and confirm your choice with...
The wylerLEVEL has been calibrated at the WYLER AG head office. The inclinations displayed are exact only in that location. In other locations, the displayed value needs to be corrected. i.e. If the wylerLEVEL is set up to correct for the local gravity, the measured inclination will be corrected accordingly prior to being displayed.
Switch gravitational correction on by using the keys and confirm with Now you need to enter the value of the local gravity. The value can be set using the keys. Using the causes the standard value of 9.807 m/s to be adopted. 9.80700 Use the key to confirm your input.
5 . 1 1 F A C T O R Y R E S E T Factory Reset returns all settings to the same state they left the factory with. The wylerLEVEL is set to the following standard configuration: Standard values: Measuring mode:...
. Select [Self-Test] and confirm with The display will show an image of the wylerLEVEL, including the keys and LEDs. If a key is pressed or the wylerTRIGGER / BlueZAPPER is used, both the real LEDs those shown on the display will light.
R R O R M E S S A G E S When the wylerLEVEL starts, it conducts a function test. If an error is detected, the device must be returned to the dealer. Proper functioning cannot be guaranteed. The following error messages can occur: •...
Basic standards for EMC & ERM EN 301489-17 “ Safeties: external Power Supply +24 Volt from WYLER AG, otherwise it must comply with EN 61010-1 ! For information: On the basis of this DoC, the products will bear the following mark: Place &...
E C L A R A T I O N O F O N F O R M I T Y The wylerLEVEL is equipped with OEM Serial Port Adapter 332i with Bluetooth ® wireless technology OEM S Abstract from the connectBlue Datasheet “...
OEM Serial Port Adapter 332i with Bluetooth ® wireless technology Manufacturer: connectBlue AB Norra Vallgatan 64 SE-211 22 Malmö, Sweden Product Name: OEM SPA332i, with internal antenna (SMD-Type) OEM Module ID: cB-0902-0202 Type : Bluetooth -Class 1 RF-Output Power: + 16.9dBm (49mW)
(2.400 - 2.4835 GHz) stämmer överens med de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv 1999/5/EG. Hiermit erklärt Wyler AG, CH-8405 WINTERTHUR, dass sich „BlueSYSTEM“ und seine Geräte (2.400 - 2.4835 GHz) in Übereinstimmung mit den grundlegenden Anforderungen und den anderen relevanten Vorschriften der Richtlinie 1999/5/EG befinden.
Page 49
List of European Countries with Restrictions (ISM-Band, Class 1): Par la présente Wyler AG, CH-8405 WINTERTOUR déclare que les instruments “BlueSYSTEM et ses composants (2.400 - 2.4835 GHz) sont conforme aux exigencies essentielles et aux autres dispositions pertinentes de la directive 1999/5/CE.
Invoicing will be handled through the WYLER partner in your country. Make use of this service in order to have your WYLER device back at your disposal as soon as possible. If you have any questions, please contact WYLER AG or your local distributor. We will be glad to help you use the ERS successfully.
Page 51
E R V I C E A N D M A I N T E N A N C E A G R E E M E N T S Measuring systems are becoming more and more complex, and have to be continuously monitored with respect to quality and reliability. For this purpose, WYLER AG offers the option of a SERVICE AGREEMENT with the purchase of new devices.
Page 52
WYLER AG Tel. 0041 (0) 52 233 66 66 Im Hölderli Fax. 0041 (0) 52 233 20 53 CH-8405 WINTERTHUR Switzerland Homepage: http://www.wylerag.com E-Mail: wyler@wylerag.com Page 52 of 52 Pages V 1.0...
Need help?
Do you have a question about the wylerLEVEL and is the answer not in the manual?
Questions and answers