Page 2
ONTENT UBJECT NTRODUCTION 1.1. CLINO ESCRIPTION OF THE REPARATION AND TART 1.2.1 ATTERIES 1.2.2 POSSIBLE CONFIGURATIONS TARTING PERATION HORT DESCRIPTION 2.1.1 VERVIEW KEYBOARD AND DISPLAY 2.1.2 OW TO SWITCH THE INSTRUMENT 2.1.3 UNCTIONS HORT DESCRIPTIONS OF EACH SINGLE KEY ISPLAY 2.2.1 CALING THE DISPLAY 2.2.2...
Page 3
BSOLUTE MEASURMENT WITH COMPENSATION OF ZERO OFFSET ) / ABSOLUTE ZERO M EVERSAL MEASUREMENT / REL ZERO M ELATIVE EASUREMENT / UNIT ETTING OF THE MEASURING UNIT / LIMITS ETTING OF IMITS / FILTER ETTING THE ILTER YPES / JOIN ROUPING OF NSTRUMENT WITH WIRELESS TRANSMISSION / LEAVE...
Page 4
INDEX Key word Chapter Page BSOLUTE MEASURMENT ELATIVE MEASUREMENT ZERO / ZERO-S BSOLUTE ETTING ZERO / ZERO-S 3.1.1 BSOLUTE ETTING APPENDICES 2.2.3 ACKGROUND COLOUR 1.2.1 ATTERIES METER 1.2.2 1.2.2 LUETOOTH 2.2.4 RIGHTNESS CARE AND HANDLING OF THE BATTERIES TORAGE 1.2.2 ONFIGURATIONS ONTENT ( >10...
ANUFACTURERS ECLARATION OF ONFORMITY EASURING UNIT ON/OFF CLINO PERATING INSTRUCTIONS PERATION HORT DESCRIPTION PTIONS 2.1.1 VERVIEW KEYBOARD AND DISPLAY PIN-C PIN-DEFINITION FOR B CLINO 1.2.2 OSSIBLE ONFIGURATIONS REPARATION AND TART ROGRAMMABLE UICK CALIBRATION 4.10 UICK ALIBRATION ESET UICK ALIBRATION ON/OFF ADIO REL ZERO 3.5.2...
RIOR TO STARTING Please read this manual prior to working with the BlueCLINO. You will get an overview on all the functions and possibilities of this instrument. At the same time you get familiar with the handling of the instrument and wrong handling and specifically the unintentional erasing of the calibration data can be avoided.
Page 7
ONFIGURATIONS Stand-alone instrument BlueCLINO connected to the RS232 port of a PC BlueCLINO connected to a BlueMETER or BlueTC via Bluetooth and then connected to a the RS232 port of a PC BlueCLINO connected to a BlueMETER via cable BlueCLINO connected to a BlueMETER via Bluetooth Please check the respective manuals and data sheets for details on the other products shown above.
TARTING PERATION HORT DESCRIPTION 2.1.1 O VERVIEW KEYBOARD AND DISPLAY Querlibelle Setting vial Fiole transversale Tasten Keys Hauptanzeige Touches Main display Affichage principale 0.400 Masseinheiten Measuring units Unités de mesure M1234 mm/m Seriennummer Serial Number Externer Anschluss Numéro de Série External connection Connexion externe Funktionsanzeige und Anzeige Infrarot...
Page 9
2.1.2 H OW TO SWITCH THE INSTRUMENT The BlueCLINO features an automatic shut off. In normal mode the instrument is automatically switched off 60 minutes after the last key operation. This automatic shut OFF function can be deactivated with a special...
Page 10
= 0 ... 255 – Continuous number xxxxxx = Sensor Serial Number and Type (example: N2673L BlueCLINO ) sn.nn sn.nnnnnn = inclination in rad, e.g. +0.226349 +9.999999 -> Positive Overrange -9.999999 -> Negative Overrange Format of transmission: asynchron, 7Bit, 2 Stopbits, no parity, 9600 Baud Function - 2 - Unfreeze of the "HOLD"- function to return to the measuring mode.
Page 11
Function - 1 - The key serves for "freezing" a measuring value. The value is displayed until the BlueCLINO returns to the measuring mode by pressing the key. Function - 2 - In the functions "REL.ZERO" and "ABS.ZERO" the key is used for reading in the actual measuring value again during the manual entering.
ISPLAY The BlueCLINO features various graphic displays which can be scaled according to the requirements of the measuring task. Also the background colour and the brightness of the display can be adjusted. 2.2.1 S CALING OF THE ISPLAY For an optimal use of the graphic display, you have various options for scaling.
Page 13
The following display types are available in the BlueCLINO: Numeric display Numeric display plus bar graph Display ranges: 60°, 45°, 20°, 10°, 5°, 2°, 1°, 30', 12' Numeric display plus 3 bars, each with a 10 times higher resolution Display ranges: 60°, 45°, 20°, 10°, 5°, 2°,...
Page 14
Numeric display plus pin Display ranges: 60°, 45°, 20°, 10°, 5°, 2°, 1°, 30', 12' 2.2.3 B ACKGROUND COLOUR In the adjustments of the instrument the background colour can be selected. Depending on the brightness of the colour selected the colour of the fonts and the symbols will change between black and white. Using the key select the menu point [Optionen] and confirm with...
Page 15
The following background colours are available in the BlueCLINO: Background colour blue Background colour black Background colour beige Background colour orange page 16 of 84 pages...
Page 16
2.2.4 B RIGHTNESS Adjustment of the brightness of the display. Difference between battery operation and the use of an external power supply. In the adjustments of the instrument the brightness of the display can be adjusted in order to adapt it to the environmental conditions and to optimise the battery life time.
Page 17
HORT DESCRIPTION OF THE INDIVIDUAL DISPLAY AREAS Main In the main display the actual measuring value will be displayed. display Display of the A symbol indicates the direction of the inclination of the value direction of the displayed. inclination inclined to the right (positive inclination) declined to the right (negative inclination)
Page 18
Mark the precise position and particularly the direction of the BlueCLINO in order to be able to turn the instrument by 180 degrees and to put it in opposite direction at the very same spot.
Page 19
Notice: The value of the "ZERO OFFSET" determined by a reversal measurement corresponds to the deviation of the zero point of the BlueCLINO compared to the absolute Zero (gravity). The displayed measuring value corresponds to VALUE displayed = Value of the BlueCLINO minus "ZERO OFFSET"...
Depending on the unit selected the last digit will be rounded to 5" or to the nearest lower integer (e.g.20 µmm/m). For the BlueCLINO HP 1° the rounding will be to 0.2" for the BlueCLINO HP 5° to 1". 3.2.2 U NITS WITH RELATIVE BASE LENGTH The units mm/REL and "/REL are related to a relative, this means selectable, base length.
Page 21
The key function can be applied in all measuring modes. Put the BlueCLINO on a stable support. Press now the key . While the BlueCLINO is waiting for a valid measuring value the display will show graphically the measuring values read in the form of a shoal of points.
Page 22
3.5.1 BSOLUTE MEASUREMENT As a factory setting the BlueCLINO will be programmed for absolute measurement (default setting). If this is not the case select the function [Absolute]. After confirming this function with the key the instrument is ready for measurements in the mode "ABSOLUTE".
Page 23
OFFSET", e.g. determined by a reversal measurement. The "REL ZERO OFFSET" will be stored in the BlueCLINO and can be re-called again and again. When starting the next relative measurement the "REL ZERO OFFSET" entered or determined the last time will be displayed.
Page 24
Set the BlueCLINO to the correct position and press the key . Alternatively the measuring can also be started using the zapper.
Page 25
"0". With the key the value displayed will be stored and the procedure terminated. With the key the procedure will be abandoned without change. After that the BlueCLINO will return to the measuring mode.
Page 26
[sss xxxxxt LL sn.nnnnnn sm.mmmmmm<cr>] sss = 0 ... 255 - continuous number xxxxxt = Sensor Serial Number and Type N2673L BlueCLINO sn.nnnnnn = +9.999999 - Positive Overrange -9.999999 - Negative Overrange other value - angular value in rad e.g. +0.226349 sm.mmmmmm =...
Page 27
To make sure that the instrument does not belong to another group, it is advisable to perform the function "LEAVE" first. 1. On the BlueCLINO select the menu "JOIN" using the key. Confirm with Set the second instrument also to the JOIN mode.
Page 28
Each instrument may be unhinged individually from an existing measuring group. "LEAVE" ROCEDURE 1. On the BlueCLINO select the menu "LEVAE" using the key. Confirm with 2. The BlueCLINO is now unhinged from the group and is no longer accessible via wireless data transmission. page 29 of 84 pages...
Page 29
UICK CALIBRATION ONLY POSSIBLE WITH QUICK CALIBRATION OPTION The BlueCLINO is equipped with an integrated calibration set-up for a quick calibration procedure which enables the calibration without complex means. On the backside of the instrument precisely manufactured and placed holes are available for installing the dowel pins as calibration aids. These pins are part of the delivery and can be inserted into the holes.
Page 30
Finally the correction of the zero point (absolute Zero) must be determined by a reversal measurement. The BlueCLINO has now been re-calibrated and can be used for further measurements. The calibration aids (dowel pins) delivered must be stored cleaned and grease applied.
Page 31
TEACH-IN of the IR-trigger (Zapper) In order to eliminate interference of the zapper signals when several measuring groups are active in the triggering range the IR trigger can be assigned to a specific measuring group by applying the function TEACH-IN Procedure TEACH-IN: ...
Page 32
PTIONS The options serve for entering the basic adjustments of the measuring instrument. The access to the options can be protected with a PIN code in order to avoid unauthorised modifications. The following options are available: Option "Set PIN-Code" With this option it is possible to block the entering of options with a PIN code.
Page 33
PIN-C In order to protect the settings of the BlueCLINO against unauthorised changes you have the possibility to block the entering of options with a password. Using the key select the menu point [Options] and confirm with . Select now [Set Pin Code] and confirm with...
Page 34
Using the key select the menu point [Optionen] and confirm with . Select now [Display Settings] and confirm with Display Settings -> Brightness Brightness Battery Color With the keys select the display option you would like to change and confirm the selection with the key In the brightness adjustments you can increase or reduce the brightness using the keys .
Page 35
ROGRAMMABLE The function of the keys as well as the key can be switched on or off. Using the key select the menu point [Optionen] and confirm with . Select now [Programmable keys] and confirm with Programmable Keys -> - Rel.Zero {ON} Select the key you want to activate or deactivate using the keys - Scale {ON} and confirm your choice with the key...
Page 36
ON/OFF UNCTIONS The menu functions provided can be switched on respectively off. Thus the menu displayed can be adjusted to the needs of the user. Using the key select the menu point [Optionen] and confirm your selection with . Select now [Functions ON/OFF] and confirm with Functions ON/OFF ->...
Page 37
Radio RAVITATION The inclination displayed by the BlueCLINO is based on the gravitation. Around the globe the gravitation is, however, not constant but it varies with the latitude and with the height above sea level. Furthermore variations of the density in the lithosphere cause additional local deviations.
Switch the correction of the gravitation ON or OFF using the keys and confirm with the key Now you can enter the value of the local gravity. The value is adjusted with the keys . With the key standard value 9.80700 m/s will be recalled.
Page 39
ACTORY ESET A complete factory reset will reset the instrument to the state as it has been configured at the factory. All personal settings are lost. The BlueCLINO will be set to the following standard configuration: Standard-Werte: measuring mode: absolute measuring unit: DEC xx°xx'xx"...
Page 40
. Select now [Self Test] and confirm with In the display a simplified design of the front foil of the BlueCLINO will be shown. If any key or the IR zapper is pressed, the real LEDs as well as those on the display will lit. In addition the key pressed will be marked.
Page 41
APPENDICES LOAT HARTS GENERAL ON/OFF TART THE INSTRUMENT page 42 of 84 pages...
Page 67
XAMPLE USING THE YPER ERMINAL OF INDOWS OR INDOWS WIN XP) ERMINAL PROGRAM XAMPLE IS 1. Open the Terminal-Program in Windows / Accessories. and insert a name Confirm with <OK> 2. Enter the serial port definition connected to the BlueMETER. Confirm with <OK>...
Page 68
Example: BlueCLINO with address 50 is connected: Meaning of the display: Continuous number (3 measurements per second will be performed continuously) N2673 Serial Number of the instrument Type of instrument: BlueCLINO -0.006826 - 0.006826 Rad bzw.- 6826 µRad page 69 of 84 pages...
Page 69
Error Messages After the start of the instrument the BlueCLINO performs a function check. If any defects are detected instrument must be returned to the distribution partner. A proper functioning can not be guaranteed. The following error messages may appear: Display is blinking grey mottled.
Page 70
PARE ARTS CCESSORIES The following spare parts are available: - Batteries, NC-accumulators - various cables - Infra-red Zapper page 71 of 84 pages...
Page 71
& E (WEEE) IRECTIVE ON ASTE LECTRICAL LECTRONIC QUIPMENT page 72 of 84 pages...
Page 73
Basic standards for EMC & ERM EN 301489-17 “ Safeties : external Power Supply +24 Volt from WYLER AG, otherwise it has to comply with EN 61010-1 ! For information: On the base of this DoC, the products will bear following mark: Place &...
Page 74
BLUETOOTH ECLARATION OF ONFORMITY OF THE MANUFACTURER OF THE MODULE ™ CLINO OEM S IS EQUIPPED WITH ERIAL DAPTER I WITH LUETOOTH WIRELESS TECHNOLOGY "OEM S " BSTRACT FROM THE CONNECT ATASHEET ERIAL DAPTER B-OEMSPA312 / 332, B-0902 & M LECTRICAL ECHANICAL ATASHEET...
Page 75
CLINO-I OEM S NSTRUMENT IS EQUIPPED WITH ERIAL DAPTER I WITH ™ LUETOOTH WIRELESS TECHNOLOGY ANUFACTURER CONNECT ORRA ALLGATAN SE-211 22 M ALMÖ WEDEN OEM SPA332 (SMD-T RODUCT WITH INTERNAL ANTENNA OEM M ID : B-0902-0202 ODULE LUETOOTH LASS RF-O : + 16.9 UTPUT OWER...
Page 76
(2.400 - 2.4835 GHz) stämmer överens med de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv 1999/5/EG. Hiermit erklärt Wyler AG, CH-8405 WINTERTHUR, dass sich „BlueSYSTEM“ und seine Geräte (2.400 - 2.4835 GHz) in Übereinstimmung mit den grundlegenden Anforderungen und den anderen relevanten Vorschriften der Richtlinie 1999/5/EG befinden.
Page 77
List of European Countries with Restrictions (ISM-Band, Class 1) : Par la présente Wyler AG, CH-8405 WINTERTOUR déclare que les instruments “BlueSYSTEM" et ses composants (2.400 - 2.4835 GHz) sont conformes aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999/5/CE.
Page 78
ECHNICAL Measuring range/ ± 60 Arcdeg Messbereich Value available after / Settling time / < 5 sec. Anzeige nach Messzeit Resolution Depending on units set 5 Arcsec ( 0.025 mm/m) Abhängig von ausgewählter Auflösung Masseinheit Limits of error within 6 months (TA = 20ºC)* / <...
Page 79
PIN-DEFINITION FOR B CLINO RS232 / RS485 Binder Series 712 8 pol. (female) RS485 Signal Pin Type Pin Function Power in Unregulated Power Ground Power out Power +5V Input/Output RS485-Line A Input/Output RS485-Line B KEY* Input Trigger Key RS232 Signal Pin Type Pin Function Power in...
Page 80
The invoicing will be through the WYLER partner in your country. Please do not hesitate to make use of this service in order to have your WYLER instrument back at your disposal as soon as possible. In case of any questions please contact WYLER SWITZERLAND or your local distributor, we will gladly help you to use the ERS successfully.
Page 81
ONTRACTS Measuring systems are becoming more and more complex and are therefore subject to continuous supervision in respect of quality and reliability. For this purpose WYLER AG offers the option of a MAINTENANCE CONTRACT with the purchase of new instruments.
Need help?
Do you have a question about the BlueCLINO and is the answer not in the manual?
Questions and answers