  • Page 1 OPERATION, MAINTENANCE AND SAFETY INSTRUCTIONS FOR OMEGA ALTISE AIR CONDITIONER Model : OAPC36RW OMEGA ALTISE...
  • Page 2: Table Of Contents

    Contents IMPORTANT SAFETY INSTRUCTIONS ......................3 TECHNICAL DETAILS ............................8 FEATURES ............................... 9 PRODUCT OVERVIEW ............................ 9 INSTALLATION INSTRUCTIONS ........................10 OPERATING INSTRUCTIONS ........................14 CLEANING ..............................18 SERVICING ..............................20 TROUBLESHOOTING ............................ 22 WARRANTY ..............................23 OMEGA ALTISE...
  • Page 3: Important Safety Instructions

    If you are unsure about anything regarding your fan or these instructions, please contact Omega Altise on 1300 795 572 in Australia or (09) 415 6000 in New Zealand before operating your appliance •...
  • Page 4 • WARNING: The appliance shall be stored in a room without continuously operating open flames (for example an operating gas appliance) and or other potential ignition sources (for example an operating electric heater, hot surfaces). OMEGA ALTISE...
  • Page 5 If a leakage of refrigerant is found which requires brazing, all of the refrigerants shall be recovered from the system, or isolated (by means of shut off valves) in a part of the system remote from the leak. OMEGA ALTISE...
  • Page 6 Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of recovered refrigerant. It is essential that electrical power is available before the task is commenced. (a) Become familiar with the equipment and its operation. (b) Isolate system electrically. OMEGA ALTISE...
  • Page 7 The evacuation process shall be carried out prior to returning the compressor to the suppliers. Only electric heating to the compressor body shall be employed to accelerate this process. When oil is drained from a system, it shall be carried out safely. OMEGA ALTISE...
  • Page 8: Technical Details

    To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmentally safe recycling. TECHNICAL DETAILS Model OAPC36RW Fan Speeds 3 settings Cooling Capacity 12000 Btu/h (3.52KW) Heating Capacity 9800 Btu/h (2.87KW)
  • Page 9: Features

    2. Air outlet with adjustable louver 3. Air outlet with adjustable louver 4. Power cord 5. Recessed handle 6. Air exhaust 7. Drain opening with sealing plug Note: The appearance is only for reference. Please see the real product for detailed information. OMEGA ALTISE...
  • Page 10: Installation Instructions

    Unpack the carton and take the appliance and accessories out. • Check the device after unpacking for any damage or scratches on it. • Accessories: 1. Exhaust hose 2. Hose connector 3. Window kit adapter 4. Remote control 5. Window kit OMEGA ALTISE...
  • Page 11 Do not replace or extend exhaust hose which will result in decreased efficiency, even worse shut down the unit due to low backpressure. Step 1: Connect the hose connector to one end of the exhaust hose. OMEGA ALTISE...
  • Page 12 Step 4: Close your window to secure the kit in place. It needs to hold the windows kit firmly in place, secure the window kit with duct tape if required. It is recommended that the gap between the adapter and the sides of the window should be sealed off for maximum efficiency. OMEGA ALTISE...
  • Page 13 Step 6: Adjusting the length of the flexible exhaust hose and avoid bends in the hose. Then place AC near an electrical outlet. Step 7: Adjust the louver at the air outlet, and then switch on the unit. OMEGA ALTISE...
  • Page 14: Operating Instructions

    Press to switch the fan speed in HIGH(green)、 middle(green)and LOW (green) INDICATORS LED for fan speed (Low, middle and high) DIGITAL Displays timer setting and room temperature DISPLAY Decreasing the desired temperature or timer MINUS setting SLEEP Press to turn sleep mode on or off OMEGA ALTISE...
  • Page 15 Press SPEED button repeatedly until the desired fan speed indicator lights up. To control the direction of the air flow horizontally, press the SWING button. • Note: The air conditioner stops if the room temperature is lower than selected temperature. OMEGA ALTISE...
  • Page 16 Then the temperature is kept constant for 10 hours. And all the indicators dim to dark. The fan speed may switch over to low speed for silent operating and cannot be selected. TIMER SETTING The timer has two ways of operation: OMEGA ALTISE...
  • Page 17 As the negative pressure of condensate drain pan is large, tilt the drain hose downward toward the floor. It is appropriate that the degree of inclination should exceed 20 degrees. • Straighten the hose to avoid a trap existing in the hose. OMEGA ALTISE...
  • Page 18: Cleaning

    Warning!!! Do not touch the evaporator surface with bare-hand or could cause injury of your fingers. CAUTION: Do not use gasoline, benzene, thinner, harsh cleaners, etc. as they will damage the appliance. NEVER use ALCOHOL OR SOLVENTS. OMEGA ALTISE...
  • Page 19 7. Stop the source of the release, if safe to do so. Consider the use of water spray to disperse vapours. 8. Isolate the area until gas has dispersed. Ventilate and gas test area before entering. Contact competent authorities after a spill. OMEGA ALTISE...
  • Page 20: Servicing

    If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence • of refrigerant. Marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall • be corrected. OMEGA ALTISE...
  • Page 21 That there no live electrical components and wiring are exposed while charging, recovering or purging • the system. That there is continuity of earth bonding. • WARNING! Install the unit in rooms which exceed 12 m². • Do not install the unit in a place where inflammable gas may leak. • OMEGA ALTISE...
  • Page 22: Troubleshooting

    It is important that you retain these instructions, proof of purchase as well as other important documents about this product for future reference. Due to continual product development, Omega Altise reserves the right to alter specifications or appearances without notice. Dispose of packaging responsibly – recycle where facilities are available.
  • Page 23: Warranty

    WHAT IS COVERED: By Our Warranty: During the warranty period, Omega Altise or its authorised Service Centre will at no extra charge, if your appliance is readily accessible without the need of special equipment and subject to the terms and conditions of this warranty, repair or replace any parts which it considers defective.