( 4 ) PW SR (Pulse width trigger SYNC-RESET)

The trgger input to the RGB terminal develops 1 frame images.

(4. 1) 1 Pulse Width Trigger SYNC-RESET Picture Output Timing

Trigger*
1
VD OUT *
3
Video output
VIDEO INDEX
*1: Externally input signal
*2: Exposure time = Trigger pulse width + 6 s
(Valid trigger pulse width is 2 s or greater for external trigger shutter operation.)
*3: VD is generated after 0 to 1H following the completion of the exposure period and the video is synchro-
nized to this and output.
Note:
When the next trigger is input before completion of the output of the video corresponding to the trig-
ger, there will be an effect on the video.
IK-TF7(E)
About 1 s
About 7 s
Exposure period*
Exposure completion
0 to 1H