Page 1
Bias D1/Q1/Q2 Powering the future of sound U S E R G U I D E V 2 . 0...
Page 2
For the latest online version, visit: www.voidacoustics.com Void Acoustics and the Void logo are registered trademarks of Void Acoustics Research Ltd. in the United Kingdom, USA and other countries; all other Void trademarks are the property of Void Acoustics Research Ltd.
DISCONNECT THE AC MAINS SOURCE BEFORE ATTEMPTING TO CLEAN ANY PART OF THE AMPLIFIER CLASS3 WIRING VOID SUGGESTS TO PLUG THE BIAS D1/Q1/Q2 SERIES TO A 16 A RATING, C OR D CURVE, 10 kA SECTIONING BREAKER. CLASS3 WIRING OUTPUT TERMINALS ARE HAZARDOUS: WIRING CONNECTION TO THESE TERMINALS...
2) this device must accept any interference received, including interference that may cause undesired operation. CAUTION: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
The box contains the following: When On, Energy Save is active on each channel independently. 1x Bias D1 amplifier. If the signal is missing for more than 30 minutes on all channels, 1x Phoenix MC 1,5/4-ST-3,81 - 1803594 plug...
ArmoníaPlus software. and activate an alert through the general purpose output switch. Void recommend the use of Ethernet Cat5 straight through – The output pilot tone detection relies on an external signal passing patch – cables with pin/pair assignments TIA/EIA-568-B, i.e. T568B.
Page 8
Location Cooling 1 RU 1 RU 1 RU Exposing the Control Panel Dimensions 442 mm 19.0 in Page 8...
Color code (TIA/EIA-568-B) ORANGE / WHITE ORANGE GREEN / WHITE Ethernet and Dante ports BLUE BLUE / WHITE Ethernet port (RJ45) GREEN BROWN / WHITE Dante port (RJ45) - Dante™ enabled versions only BROWN UG10607-2.0 - Bias D1/Q1/Q2 User Guide V2.0...
AUTO STANDBY BLINKING 1. An 8Ω dummy load is needed to measure the output current. If the dummy — ORANGE ERROR CODE BLINK COUNTER load is not applied the system reports a fault. UG10607-2.0 - Bias D1/Q1/Q2 User Guide V2.0...
Page 12
H E A D O F F I C E Void Acoustics Research Ltd, Unit 15, Dawkins Road Industrial Estate, Poole, Dorset, BH15 4JY United Kingdom Call: +44(0) 1202 666006 Email: info@voidacoustics.com voidacoustics.com Void Acoustics Research Limited is a company registered in England and Wales registration number 07533536...
Need help?
Do you have a question about the Bias D1 and is the answer not in the manual?