lan2de.c02
Installation
HiPath HG 1500 boards
Table 2-1
* = 2 boards may be operated in parallel
OfficeCom, old HW, CBFC: S30810-Q2950-X
OfficeCom, new HW, CBPC: S30810-Q2932-A201
Table 2-2
System type
OfficeCom/Point
OfficeCom/Point
OfficeCom/Point
OfficeCom/Point
2 simultaneous Voice over IP connections are possible for each DSP (Digital Signal
Processor).
Interfaces/connectors
The LAN port is linked at the X3/X4 connectors. For connector assignment, see
Table
2-3.
The board is equipped with a 50-pin edge connector to the system, two Western
sockets (8-pin, 10-pin shielded) to the LAN and a shielded MiniDin socket (6-pin) for
the V.24 interface:
X1: 50-pin to the system
X2: 6-pin shielded MiniDin socket for V.24 interface, see
The following connection option is provided for connection to a LAN:
X3: 8-pin Western socket for LAN 10/100 Base-T, RJ45 socket (twisted pair)
for station
X4: 8-pin Western socket for LAN 10 Base-T, RJ45 socket (twisted pair)
for trunk connection (for HXGS2 board with 2nd LAN interface only)
2-2
HXGS application option/slot
Possible application
HXGS hardware variants
Services
Data only
Voice/Data
Data only (2nd LAN)
Voice/Data (2nd
LAN)
Boards
DSPs
Board ID
0
HXGS
4
HXGS
0
HXGS2
4
HXGS2
Section 2.1.1.1
A31003-K5020-S100-6-7620
For internal use only