1. IMPORTANT SAFETY INSTRUCTIONS, SAVE THESE INSTRUCTIONS This manual contains important instructions for Model UPS series that should be followed during installation and maintenance of the UPS. Unplug the unit from the AC outlet and make certain of all switches are in the “off”...
1.2 SAFETY CAUTION: This unit is should be installed from service personnel. The equipment can be operated by any individuals with no previous experience. The socket-outlet shall be installed near the equipment and easily accessible. Attention, hazardous through electric shock. Also with disconnection of this unit from the main, hazardous voltage still may be accessible through supply from battery.
Two-Step battery charger (first with cyclic charging voltage; second with stand by charge voltage) to prolong battery life and fully charge the battery. With actually overload protection both in line and battery mode. 2.3 OUTLOOKING OVER LOAD LINE NORMAL BAT. IN USE MODEL-UPS-250...
UPS-200/250/400 Front Side View UPS-200/250/400 Rear Side View 1 BRAND NAME 2 POWER SWITCH 3 OUTLET SOCKET 4 INLET SOCKET 3 INSTALLATION AND OPERATION 3.1 SITE SELECTION...
This unit can be installed besides the computer or equipment, do not install it in non-ventilated areas. 3.2 Unpacking The following items are included in the carton User’s manual. Power cord. 3.3 Connecting the UPS For UPS series: Use the power cord to connect the wall power (utility power) and inlet socket.
flash and buzzer will be slowly beeping. 3.4.2 Turn on the computer, if it is over loaded, the LED and buzzer will rapidly flash and beep, you should check the power rating of the loaded equipment then remove the less critical one. Generally, the total power consumption of one set of personal computer (color monitor) will not exceed the rating of this UPS.
A few helpful hints: -Periodically vacuum dust from ventilation openings. -Occasionally wipe exterior with a damp cloth. 5 TROUBLESHOOTING fails operate TROUBLESHOOGING CHART. If the unit is to be returned for service, please note the following information and pack it in the original carton . a.
1) Unplug unit from AC power source and disconnect all connected equipment. 2) Disconnect AC power cord from unit. 3) Turn unit upside down and using a phillips screws driver, unscrew the 4 screws holding the top of the unit to bottom. Put screws in a safe place for reconnection.
+48℃(+86 to +118.4℉), charge the UPS’s battery every 3 months. SPECIFICATIONS MODEL INPUT Capacity Voltage Frequency OUTPUT Voltage (on battery) UPS200 UPS-250 UPS-400 200VA 250VA 400VA 100V,115V,230V 50 or 60 Hz +/-5% (auto sensing) Simulated sine wave at Line Input +/-5%...