Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Mitsubishi Electric Manuals
Heating System
Ecodan HUS210FTC4ST
Installation manual
Cylinder Technical Data - Mitsubishi Electric Ecodan HUS210FTC4ST Installation Manual
Pre-plumbed cylinder with ftc4 control system
Hide thumbs
1
2
Table Of Contents
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
page
of
85
Go
/
85
Contents
Table of Contents
Troubleshooting
Bookmarks
Table of Contents
Advertisement
Cylinder Technical Data
8
Nominal domestic hot
water storage volume
(litres)
Overall Cylinder
Dimensions
Cylinder
Weight / kg
Fully Packaged
Weight / kg
Unvented
Store
Expansion
Vessel
Control / relief valve
pressure settings
Backup Immersion
Heater Rating
Insulation
Thickness
Ozone Depletion
Potential
Global Warming
Potential
Heat pump circuit
circulating pump
DHW circuit
zone valve
CH circuit
zone valve
Standing
Losses
Control &
overheat safety
thermostat
temperature settings
Wireless Room
Thermostat
Wireless
Receiver
Main
Controller
HU150FTC4 ST
HU180FTC4 ST
150
180
H x D / mm
1281 x 550
1281 x 550
Empty
44.1
49.5
87.4
92.8
Nominal
12
19
Volume
(litres)
Charge
3.0
3.0
Pressure
(bar)
Mains Inlet
3.0 bar
3.0 bar
Pressure
Regulator
Expansion
6.0 bar
6.0 bar
Relief Valve
(CW)
P & T
7.0 bar & 90c
7.0 bar & 90c
Valve
3 kW
3 kW
50mm
50mm
0
0
< 5
< 5
22mm (1no.)
22mm (1no.)
22mm (1no.)
22mm (2no.)
1.38
1.63
Control
>65˚C
>65˚C
stat
85 °C ± 5°C
85 °C ± 5°C
Overheat
Stat
HU210FTC4 ST
HU250FTC4 ST
HU300FTC4 ST
210
250
300
1469 x 550
1719 x 550
2032 x 550
53.3
58.8
67.7
97.7
103.2
113
19
19
24
3.0
3.0
3.0
3.0 bar
3.0 bar
3.0 bar
6.0 bar
6.0 bar
6.0 bar
7.0 bar & 90c
7.0 bar & 90c
7.0 bar & 90c
3 kW
3 kW
3 kW
50mm
50mm
50mm
0
0
0
< 5
< 5
< 5
UPS2 25-60 130 (2no.)
22mm (1no.)
22mm (1no.)
22mm (1no.)
22mm (2no.)
22mm (2no.)
22mm (2no.)
1.90
2.21
2.43
>65˚C
>65˚C
>65˚C
85 °C ± 5°C
85 °C ± 5°C
85 °C ± 5°C
OPTIONAL - PAR-WT50R-E
OPTIONAL - PAR-WR51R-E
Main RC
HUS210FTC4 ST
HUS250FTC4 ST
HUS300FTC4 ST
210
250
300
1719 x 550
1719 x 550
2032 x 550
58.9
64.4
76.9
102.2
108.6
122.2
19
19
24
3.0
3.0
3.0
3.0 bar
3.0 bar
3.0 bar
6.0 bar
6.0 bar
6.0 bar
7.0 bar & 90c
7.0 bar & 90c
7.0 bar & 90c
3 kW
3 kW
3 kW
50mm
50mm
50mm
0
0
0
< 5
< 5
< 5
22mm (1no.)
22mm (1no.)
22mm (1no.)
22mm (2no.)
22mm (2no.)
22mm (2no.)
1.90
2.21
2.43
>65˚C
>65˚C
>65˚C
85 °C ± 5°C
85 °C ± 5°C
85 °C ± 5°C
FTC4 Installation Manual
11
Table of
Contents
Previous
Page
Next
Page
1
...
8
9
10
11
12
13
14
15
Advertisement
Table of Contents
Related Manuals for Mitsubishi Electric Ecodan HUS210FTC4ST
Heating System Mitsubishi Electric ecodan Quick Start Manual
(16 pages)
Heating System Mitsubishi Electric ECODAN EHPT20Q-VM2EA Operation Manual
Cylinder unit (66 pages)
Heating System Mitsubishi Electric City Multi R2 Series Installation Manual
Air-conditioners for building application (62 pages)
Heating System Mitsubishi Electric EHSC-VM6A Service Manual
Hydrobox, main controller (66 pages)
Heating System Mitsubishi Electric EHPT20Q-VM2EA Service Manual
Cylinder unit (81 pages)
Heating System Mitsubishi Electric ECODAN EHSC-VM6D-CN Operation Manual
Hydrobox (20 pages)
Heating System Mitsubishi Electric VL-250CZPVU-R-E Installation Manual
Lossnay heat recovery ventilator (residential use) (46 pages)
Related Content for Mitsubishi Electric Ecodan HUS210FTC4ST
ecodan Hot Water Cylinder
Mitsubishi Electric ecodan
This manual is also suitable for:
Ecodan hus250ftc4st
Ecodan hus300ftc4st
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL